V7 Ducted Series. The necessary air conditioners for your business!

  • Adjustment of static pressure and air supply
  • Scheduling the operation of the air conditioner according to your needs
  • Excellent protection thanks to the gold hydrophilic coating of the element
  • Easy installation thanks to the very slim design
  • Check the air conditioner from wherever you are for ideal conditions in your place

Flexibility, absolute control & high performance!

5 Year Warranty for all Inventor Air Conditioners

All Inventor Air Conditioners are accompanied with a 5-year warranty card. Their high production quality ensures their impeccable performance and long term operation, even in the most demanding conditions.

Eurovent certification

Features

Static Pressure/ Air Flow Volume Settings

With the advanced technology of the new air Duct units, you can set either the available static pressure or the air flow volume depending on your plant’s duct network.

Weekly Planner Controller

Take advantage of the Weekly Planner and adjust according to your needs, the air conditioner’s operating period, ensuring maximum energy and money savings. The new advanced wired controller, shows up the error codes and additionally enables you to activate the room temperature sensor via the wired controller instead of the air conditioner.

Golden Fin

The ultimate protection of the air conditioner, especially at areas with high humidity levels and increased corrosive possibility, such as islands and coastal areas, can now be achieved. The golden, anticorrosive coating of the outdoor unit’s refrigerant, protects against salty air, rain and other corrosive elements, ensuring the effective performance of the air conditioner and the extension of its lifeline. The golden coating of the indoor unit refrigerant, thanks to its antibacterial action, allows you to enjoy a perfectly clean and healthy atmosphere!

Super Slim Design

Smaller indoor unit’s height compared to the conventional ones to ensure easy installation in the smaller places.

Wi-Fi Ready

Control your climate easily from wherever, with your Smartphone or Tablet. Download the app, Invmate II, for free via Google Play & App Store and set your temperature conditions.

Static Pressure Settings

Weekly Planner Controller

Golden Fin

Super Slim Design

Wi-Fi Ready

Control your climate easily from wherever, with your Smartphone or Tablet. Download the app, Invmate II, for free via Google Play & App Store and set your temperature conditions.

BMS Connectivity

Complete your connected products portfolio by integrating Inventor air conditioners into your BMS (Building Management System). Create an integrated ecosystem that includes air conditioning, ventilation, lighting, and security systems, fully alignment with your building’s needs. Enjoy quick, easy, and efficient management of all these different systems through central management and achieve optimum efficiency and comfort in your building.

Benefits

Built-in Drain Pump

The drain pump can lift the condensing water up to 750mm, serving every kind of installation. Refers to chest installations.

Fresh Air Intake

Provided to handle the fresh air load for a clean and healthy environment.

Central Control Management (Optional)

The centralized multi-functional device can control up to 64 indoor units within a maximum connection length of 1200m. Control your air conditioner, set the temperature you want and select the mode you desire. Ideal for hotel & business units. *Refers to the units of 24.000~60.000btu/h

Two Air Inlet Styles

Choose between the bottom or the rear side for the air intake. It can fit all needs of the installations. Flexible air intake from the back or the bottom part of the unit.

Remote On/Off (Optional)

The variety of options provided by the pre-installed ON/OFF contact gives you the flexibility you need to manage your air conditioners, while saving time and energy. Install Door Switch or remote switches to turn units on or off easily and instantly. *Requires separate purchase of connection kit

Follow Me

A smart sensor is located on the remote control. When the Follow Me function is activated the set temperature synchronizes with the smart sensor. Your set temperature will follow you wherever you and the remote go, offering extra comfort and energy savings.

Hotel Menu

Inventor air conditioners present the innovative air-conditioning unit management "HOTEL MENU". The HOTEL MENU is a set of features specifically designed to help better and more economical operation of air conditioners installed in hotel units.

BMS Connectivity

Complete your connected products portfolio by integrating Inventor air conditioners into your BMS (Building Management System). Create an integrated ecosystem that includes air conditioning, ventilation, lighting, and security systems, fully alignment with your building's needs. Enjoy quick, easy, and efficient management of all these different systems through central management and achieve optimum efficiency and comfort in your building. *Requires separate purchase of connection kit

Error Alarm Port

Take the whole control of you unit! Thanks to the error code that will appear if an error occurs, you can always be safe and sure for the appropriate and most efficient operation of your air conditioner.

ECO mode

With the new ECO mode on your remote controller, you can set your air conditioner to operate at the lowest cost, achieving maximum energy savings & enjoying the greatest conditions in your place.

Technical Specifications

  • Cooling Capacity12.000 (1.800-13.607) Btu / h
  • Cooling Capacity3.52 (0.53-3.99) kWatt
  • Heating Capacity13.000 (3.400-14.975) Btu / h
  • Heating Capacity3.81 (1.00-4.39) kWatt
  • Seasonal
    Efficiency
    (In accordance
    to EN14825)
  • Cooling
  • Pdesign3.5 kW
  • Energy ClassA++
  • SEER6.3
  • HeatingMiddle Zone
  • Pdesign2.7 kW
  • Energy ClassA+
  • SCOP4.0
  • HeatingWarm Zone
  • Pdesign3.4 kW
  • Energy ClassA+++
  • SCOP5.1
  • Voltage/Frequency/Phase220-240/50/1 V / Hz / Ph
  • Current Input – Cooling4.75 (1.30-6.09) Α
  • Current Input – Heating4.52 (1.48-6.15) Α
  • Power Input – Cooling1.05 (0.16-1.37) kW
  • Power Input – Heating1.04 (0.30-1.39) kW
  • Air Flow Volume (High/Medium/Low)600/480/300 m³ / h
  • Outdoor Static Pressure0-60 Pa
  • Noise Level – Indoor unit
    (Low/Medium/High)
    23/29/30.5/34.5 db(A)
  • Noise Level – Outdoor unit53.6 db(A)
  • Sound Power Level – Indoor/Outdoor Unit58/62 db(A)
  • Power Supply Wire Outdoor / Fuses3×1.5 / 1×10 No x mm² / Α
  • Signal Wires4×1.5 No x mm²
  • Dimensions – Indoor Unit
    (WxDxH)
    700x450x200 mm
  • Dimensions – Outdoor Unit
    (WxDxH)
    765x303x555 mm
  • Net Weight – Indoor/Outdoor Unit17.8/26.6 kg
  • Liquid Line |Gas Line1/4″ | 3/8″
  • Refrigerant/ChargeR32/710 g
  • Operation Temperature Range –
    Cooling/Heating
    -15~50 / -15~24 °C
  • Cooling Capacity18.000 (8.700-20.000) Btu / h
  • Cooling Capacity5.28 (2.55-5.86) kWatt
  • Heating Capacity19.000 (7.500-21.000) Btu / h
  • Heating Capacity5.57 (2.20-6.15) kWatt
  • Seasonal
    Efficiency
    (In accordance
    to EN14825)
  • Cooling
  • Pdesign5.4 kW
  • Energy ClassA++
  • SEER6.5
  • HeatingMiddle Zone
  • Pdesign4.3 kW
  • Energy ClassA+
  • SCOP4.0
  • HeatingWarm Zone
  • Pdesign5.2 kW
  • Energy ClassA+++
  • SCOP5.1
  • Voltage/Frequency/Phase220-240/50/1 V / Hz / Ph
  • Current Input – Cooling7.10 (3.20-9.56) Α
  • Current Input – Heating6.80 (3.30-7.70) Α
  • Power Input – Cooling1.53 (0.71-2.15) kW
  • Power Input – Heating1.51 (0.74-1.76) kW
  • Air Flow Volume (High/Medium/Low)911/706/515 m³ / h
  • Outdoor Static Pressure0-100 Pa
  • Noise Level – Indoor unit
    (Low/Medium/High)
    26/34/38/41 db(A)
  • Noise Level – Outdoor unit56 db(A)
  • Sound Power Level – Indoor/Outdoor Unit58/65 db(A)
  • Power Supply Wire Outdoor / Fuses3×2.5 / 1×16 No x mm² / Α
  • Signal Wires4×1.5 No x mm²
  • Dimensions – Indoor Unit
    (WxDxH)
    880x674x210 mm
  • Dimensions – Outdoor Unit
    (WxDxH)
    805x330x554 mm
  • Net Weight – Indoor/Outdoor Unit24.4/32.5 kg
  • Liquid Line |Gas Line1/4″ | 1/2″
  • Refrigerant/ChargeR32/1.150 g
  • Operation Temperature Range –
    Cooling/Heating
    -15~50 / -15~24 °C
  • Cooling Capacity24.000 (11.180-27.830) Btu / h
  • Cooling Capacity7.03 (3.28-8.16) kWatt
  • Heating Capacity26.000 (9.580-28.954) Btu / h
  • Heating Capacity7.62 (2.81-8.49) kWatt
  • Seasonal
    Efficiency
    (In accordance
    to EN14825)
  • Cooling
  • Pdesign7.1 kW
  • Energy ClassA++
  • SEER6.2
  • HeatingMiddle Zone
  • Pdesign5.4 kW
  • Energy ClassA+
  • SCOP4.0
  • HeatingWarm Zone
  • Pdesign6.0 kW
  • Energy ClassA+++
  • SCOP5.1
  • Voltage/Frequency/Phase220-240/50/1 V / Hz / Ph
  • Current Input – Cooling10.20 (4.20-13.20) Α
  • Current Input – Heating9.20 (3.80-11.60) Α
  • Power Input – Cooling2.19 (0.75-2.96) kW
  • Power Input – Heating1.90 (0.64-2.58) kW
  • Air Flow Volume (High/Medium/Low)1.229/1.035/825 m³ / h
  • Outdoor Static Pressure0-160 Pa
  • Noise Level – Indoor unit
    (Low/Medium/High)
    27/37/40/42 db(A)
  • Noise Level – Outdoor unit60 db(A)
  • Sound Power Level – Indoor/Outdoor Unit62/68 db(A)
  • Power Supply Wire Outdoor / Fuses3×2.5 / 1×16 No x mm² / Α
  • Signal Wires4×1.5 No x mm²
  • Dimensions – Indoor Unit
    (WxDxH)
    1.100x774x249 mm
  • Dimensions – Outdoor Unit
    (WxDxH)
    890x342x673 mm
  • Net Weight – Indoor/Outdoor Unit32.3/43.9 kg
  • Liquid Line |Gas Line3/8″ | 5/8″
  • Refrigerant/ChargeR32/1.500 g
  • Operation Temperature Range –
    Cooling/Heating
    -15~50 / -15~24 °C
  • Cooling Capacity36.000 (9.400-38.000) Btu / h
  • Cooling Capacity10.55 (2.75-11.14) kWatt
  • Heating Capacity40.000 (9.500-43.600) Btu / h
  • Heating Capacity11.72 (2.78-12.78) kWatt
  • Seasonal
    Efficiency
    (In accordance
    to EN14825)
  • Cooling
  • Pdesign10.5 kW
  • Energy ClassA++
  • SEER6.2
  • HeatingMiddle Zone
  • Pdesign8.4 kW
  • Energy ClassA+
  • SCOP4.0
  • HeatingWarm Zone
  • Pdesign9.8 kW
  • Energy ClassA+++
  • SCOP5.1
  • Voltage/Frequency/Phase220-240/50/1 V / Hz / Ph
  • Current Input – Cooling17.50 (4.20-18.50) Α
  • Current Input – Heating14.50 (3.50-17.50) Α
  • Power Input – Cooling3.95 (0.90-4.15) kW
  • Power Input – Heating3.25 (0.80-3.95) kW
  • Air Flow Volume (High/Medium/Low)2.100/1.800/1.500 m³ / h
  • Outdoor Static Pressure0-160 Pa
  • Noise Level – Indoor unit
    (Low/Medium/High)
    42/46/48/49.5 db(A)
  • Noise Level – Outdoor unit63 db(A)
  • Sound Power Level – Indoor/Outdoor Unit61/70 db(A)
  • Power Supply Wire Outdoor / Fuses3×4.0 / 1×25 No x mm² / Α
  • Signal Wires4×1.5 No x mm²
  • Dimensions – Indoor Unit
    (WxDxH)
    1.360x774x249 mm
  • Dimensions – Outdoor Unit
    (WxDxH)
    946x410x810 mm
  • Net Weight – Indoor/Outdoor Unit40.5/66.9 kg
  • Liquid Line |Gas Line3/8″ | 5/8″
  • Refrigerant/ChargeR32/2.400 g
  • Operation Temperature Range –
    Cooling/Heating
    -15~50 / -15~24 °C
  • Cooling Capacity41.000 (10.000-42.000) Btu / h
  • Cooling Capacity12.02 (2.93-12.31) kWatt
  • Heating Capacity46.000 (11.500-48.000) Btu / h
  • Heating Capacity13.48 (3.37-14.07) kWatt
  • Seasonal
    Efficiency
    (In accordance
    to EN14825)
  • Cooling
  • Pdesign12.1 kW
  • Energy ClassA++
  • SEER6.1
  • HeatingMiddle Zone
  • Pdesign9.5 kW
  • Energy ClassA+
  • SCOP4.0
  • HeatingWarm Zone
  • Pdesign10.2 kW
  • Energy ClassA+++
  • SCOP5.1
  • Voltage/Frequency/Phase220-240/50/1 V / Hz / Ph
  • Current Input – Cooling18.80 (3.10-19.80) Α
  • Current Input – Heating15.50 (3.40-18.30) Α
  • Power Input – Cooling4.20 (0.68-4.50) kW
  • Power Input – Heating3.45 (0.75-4.10) kW
  • Air Flow Volume (High/Medium/Low)2.400/2.040/1.680 m³ / h
  • Outdoor Static Pressure0-160 Pa
  • Noise Level – Indoor unit
    (Low/Medium/High)
    43/48/49/51.5 db(A)
  • Noise Level – Outdoor unit63 db(A)
  • Sound Power Level – Indoor/Outdoor Unit67/75 db(A)
  • Power Supply Wire Outdoor / Fuses3×4.0 / 1×25 No x mm² / Α
  • Signal Wires4×1.5 No x mm²
  • Dimensions – Indoor Unit
    (WxDxH)
    1.200x874x300 mm
  • Dimensions – Outdoor Unit
    (WxDxH)
    946x410x810 mm
  • Net Weight – Indoor/Outdoor Unit47.6/71.0 kg
  • Liquid Line |Gas Line3/8″ | 5/8″
  • Refrigerant/ChargeR32/2.800 g
  • Operation Temperature Range –
    Cooling/Heating
    -15-50 / -15-24 °C
  • Cooling Capacity48.000 (12.000-53.000) Btu / h
  • Cooling Capacity14.07 (3.52-15.53) kWatt
  • Heating Capacity55.000 (14.000-62.000) Btu / h
  • Heating Capacity16.12 (4.10-18.17) kWatt
  • Seasonal
    Efficiency
    (In accordance
    to EN14825)
  • Cooling
  • Pdesign14.0 kW
  • Energy ClassA++
  • SEER6.1
  • HeatingMiddle Zone
  • Pdesign11.5 kW
  • Energy ClassA+
  • SCOP4.0
  • HeatingWarm Zone
  • Pdesign11.5 kW
  • Energy ClassA++
  • SCOP5.0
  • Voltage/Frequency/Phase380-415/50/3 V / Hz / Ph
  • Current Input – Cooling8.40 (1.90-10.40) Α
  • Current Input – Heating8.00 (2.00-9.80) Α
  • Power Input – Cooling4.80 (0.88-6.00) kW
  • Power Input – Heating4.50 (0.95-5.70) kW
  • Air Flow Volume (High/Medium/Low)2.400/2.040/1.680 m³ / h
  • Outdoor Static Pressure0-160 Pa
  • Noise Level – Indoor unit
    (Low/Medium/High)
    42/47/49/50 db(A)
  • Noise Level – Outdoor unit63.5 db(A)
  • Sound Power Level – Indoor/Outdoor Unit66/74 db(A)
  • Power Supply Wire Outdoor / Fuses5×2.5 / 3×16 No x mm² / Α
  • Signal Wires4×1.5 No x mm²
  • Dimensions – Indoor Unit
    (WxDxH)
    1.200x874x300 mm
  • Dimensions – Outdoor Unit
    (WxDxH)
    952x415x1.333 mm
  • Net Weight – Indoor/Outdoor Unit47.6/103.7 kg
  • Liquid Line |Gas Line3/8″ | 5/8″
  • Refrigerant/ChargeR32/2.900 g
  • Operation Temperature Range –
    Cooling/Heating
    -15-50 / -15-24 °C
  • Cooling Capacity52.000 (14.000-59.000) Btu / h
  • Cooling Capacity15.24 (4.10-17.29) kWatt
  • Heating Capacity62.000 (15.000-70.000) Btu / h
  • Heating Capacity18.17 (4.40-20.52) kWatt
  • Seasonal
    Efficiency
    (In accordance
    to EN14825)
  • Cooling
  • Pdesign15.3 kW
  • Energy ClassA++
  • SEER6.1
  • HeatingMiddle Zone
  • Pdesign12.5 kW
  • Energy ClassA+
  • SCOP4.0
  • HeatingWarm Zone
  • Pdesign12.8 kW
  • Energy ClassA+++
  • SCOP5.1
  • Voltage/Frequency/Phase380-415/50/3 V / Hz / Ph
  • Current Input – Cooling9.60 (3.10-11.50) Α
  • Current Input – Heating9.50 (2.00-11.50) Α
  • Power Input – Cooling5.25 (1.03-6.65) kW
  • Power Input – Heating5.15 (0.95-6.60) kW
  • Air Flow Volume (High/Medium/Low)2.600/2.210/1.820 m³ / h
  • Outdoor Static Pressure0-160 Pa
  • Noise Level – Indoor unit
    (Low/Medium/High)
    43/47/49/52.5 db(A)
  • Noise Level – Outdoor unit64 db(A)
  • Sound Power Level – Indoor/Outdoor Unit66/74 db(A)
  • Power Supply Wire Outdoor / Fuses5×2.5 / 3×16 No x mm² / Α
  • Signal Wires4×1.5 No x mm²
  • Dimensions – Indoor Unit
    (WxDxH)
    1.200x874x300 mm
  • Dimensions – Outdoor Unit
    (WxDxH)
    952x415x1.333 mm
  • Net Weight – Indoor/Outdoor Unit47.4/107.0 kg
  • Liquid Line |Gas Line3/8″ | 5/8″
  • Refrigerant/ChargeR32/3.000 g
  • Operation Temperature Range –
    Cooling/Heating
    -15-50 / -15-24 °C

More

GEAR Mode

With the GEAR function you achieve great energy savings, limiting the maximum consumption of the unit. You can adjust the performance in two stages, at 75% of maximum efficiency and 50%. Take care of the right temperature in your space, reducing operating costs.

iClean Mode

The iClean function ensures the best air quality in your space, removing accumulated dust, mold and bacteria from inside the unit.

24-hour Timer

Set the unit to start and stop automatically in a 24h period.

Quiet Operation

Enjoy excellent temperature conditions and tranquil atmosphere. The advanced design of the unit, featuring larger gaps between air ducts and an improved fan tilt, facilitates airflow and ensures quiet, efficient performance. Additionally, Silent Mode further reduces noise levels, allowing you to enjoy a perfect atmosphere undisturbed.

Turbo Mode

This function gives you a boost in cooling and heating power for a period and makes the room cool down or heat up rapidly.

Sleep Mode

With the Sleep Mode, the air conditioner adjusts the room temperature for perfect sleeping conditions and great energy savings.

Weekly Program Delay (Optional with the Weekly Planner Controller)

Enjoy the flexibility offered by the Delay function, postponing the activation of the weekly schedule for up to 3 hours. Change your device settings for a specific day without changing your weekly schedule settings.

Operation Mode Lock (Optional with the Weekly Planner Controller)

Ensure the operation of your appliance in cooling or heating without interference. With the locking feature, the operation of the air conditioner cannot be changed, avoiding incorrect settings, and offering a more correct and economical operation. Ideal for workplaces or hotel rooms.

Remote Controller Commands Deactivation (Optional with the Weekly Planner Controller)

Turn off the ability to use the wireless controller to adjust your air conditioner to ensure central control of the device from a single point. Suitable for business premises and hotels.

Temperature Offset Function

The perceived temperature by the indoor unit sensor may vary from the real temperature of the room, due to the position of the unit. Thanks to this function you can minimize the difference and achieve better conditions in your place.

Anti-Cold Air Function

Indoor fan speed is regulated automatically from the lowest grade to the setting grade according to the evaporator temperature when the unit starts heating operation.

Low Ambient Cooling

The outdoor unit’s special design produces an efficient and effective cooling operation even at -15°C.

Excellent Heating Performance Under -15°C

Excellent heating performance even at the most demaning regions with low temperature levels. Ensure the prefered temperature conditions, even at -15°C and enjoy ideal conditions in your place.

Auto Error Diagnosis

Once abnormal operation or parts failure happens, the unit will shut off automatically to protect the system. Meanwhile it will indicate protection or error code for fast service.

Auto Restart

If the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.

Refrigerant Leakage Detect

Indoor unit will show error code “EC” and will stop automatically when refrigerant leakage is detected.

Mute Mode

Want to turn off the AC beep and display? By pressing the mute operation, Inventor AC helps to give you a quiet and comfortable night.

Lock

Engage the lock function to prevent anyone from changing the settings or children playing with the unit.

All DC Inverter

The fan motors of the indoor and outdoor units as well as the compressor have been upgraded to All DC Inverter technology. In this way, the compressor can change the capacity depending on the needs of the indoor atmosphere and create perfect conditions in your space.

R32 ECO Refrigerant

The R32 ECO Refrigerant with 68% lower global warming potential, is here to significantly enhance your air conditioner performance and to drastically contribute to global warming protection. It does not adversely affect the ozone layer, contributes in reducing global warming effect by entrapping smaller amounts of heat (GWP = 675) and can be easily reused and recycled.