V6MCRI32-18WiFiR/U6MRS32-18
Cooling Capacity | 18.000 Btu / h |
Heating Capacity | 18.500 Btu / h |
Cooling Capacity Range | (9.900-19.600) Btu / h |
Cooling Capacity Range | 5.28 (2.90-5.74) kWatt |
Heating Capacity | (8.100-20.800) Btu / h |
Heating Capacity | 5.42 (2.37-6.10) kWatt |
Seasonal Efficiency | Cooling In accordance to EN14825 |
Pdesign | 5.3kW |
Energy Class | A++ |
SEER | 6.1 |
Seasonal Efficiency | Heating (Middle Zone) In accordance to EN14825 |
Pdesign | 4.2kW) |
Energy Class | A+ |
SCOP | 4.0 |
Seasonal Efficiency | Heating (Warm Zone) In accordance to EN14825 |
Pdesign | 5.3 kW |
Energy Class | A++ |
SCOP | 4.9 |
Voltage / Frequency / Phase | 220-240/50/1 V / Hz / Ph |
Current Input Cooling / Heating | 7.2 (3.2-8.2) / 6.4 (3.1-8.5) A |
Power Input Cooling / Heating | 1.633 (720-1.860) / 1.460 (700-1.930) W |
Air Flow Volume (High / Medium / Low) | 720/625/540 m³ / h |
Noise Level Indoor unit (Low / Medium / High) (dB ) | 35.5/39/42.5 Low / Medium / High |
Noise Level Outdoor unit (dB ) | 55 A |
Sound Power Level Indoor / Outdoor unit (dB ) | 56/63 dB(A) |
Power Supply Wire Outdoor / Fuses | 3x2.5/1x16 No x mm² / Α |
Power Supply Wire Indoor / Fuses | 3x1.5 / 1x10 No x mm² / Α |
Signal Wires | 2 x 1.0 Shield No x mm² |
Dimensions WxDxH Panel | 647 x 50 x 647 mm |
Dimensions WxDxH Indoor unit | 570x570x260 mm |
Dimensions WxDxH Outdoor unit | 800x333x554 mm |
Net Weight Panel / Indoor / Outdoor | 2.5/16.2/33.7 kg |
Liquid line - Gas line | 1/4"/1/2" °C |
Outdoor Operation Temperature Range Cooling / Heating | -15-50 / -15-24 °C |
Refrigerant / Charge | R32/1.350 g |
Outdoor Operation Temperature Range Cooling / Heating | -15~50/-15~24 oC |
V5MCI32-24WiFiR/U5MRS32-24
Cooling Capacity | 24.000 Btu / h |
Heating Capacity | 26.000 Btu / h |
Cooling Capacity Range | (10.990-28.000) Btu / h |
Cooling Capacity Range | 7.03 (3.22-8.21) kWatt |
Heating Capacity | (8.300-29.500) Btu / h |
Heating Capacity | 7.62 (2.43-8.65) kWatt |
Seasonal Efficiency | Cooling In accordance to EN14825 |
Pdesign | 7.0kW |
Energy Class | A++ |
SEER | 6.1 |
Seasonal Efficiency | Heating (Middle Zone) In accordance to EN14825 |
Pdesign | 5.4kW) |
Energy Class | A+ |
SCOP | 4.0 |
Seasonal Efficiency | Heating (Warm Zone) In accordance to EN14825 |
Pdesign | 5.8kW |
Energy Class | A++ |
SCOP | 4.9 |
Voltage / Frequency / Phase | 220-240/50/1 V / Hz / Ph |
Current Input Cooling / Heating | 9.5 (2.1-12.4) / 8.9 (2.2-12.5) A |
Power Input Cooling / Heating | 2.190 (480-2.850) / 2.050 (500-2.880) W |
Air Flow Volume (High / Medium / Low) | 1.378/1.200/1.032 m³ / h |
Noise Level Indoor unit (Low / Medium / High) (dB ) | 40/43/47 Low / Medium / High |
Noise Level Outdoor unit (dB ) | 62 dB(A) |
Sound Power Level Indoor / Outdoor unit (dB ) | 59/64 dB(A) |
Power Supply Wire Outdoor / Fuses | 3x2.5/1x16 No x mm² / Α |
Power Supply Wire Indoor / Fuses | 3x1.5 / 1x10 No x mm² / Α |
Signal Wires | 2 x 1.0 Shield No x mm² |
Dimensions WxDxH Panel | 950x950x55 mm |
Dimensions WxDxH Indoor unit | 840x840x245 mm |
Dimensions WxDxH Outdoor unit | 845x363x702 mm |
Net Weight Panel / Indoor / Outdoor | 5/23/49.4 kg |
Liquid line - Gas line | 3/8"/5/8" °C |
Refrigerant / Charge | R32/1.500 g |
Outdoor Operation Temperature Range Cooling / Heating | -15~50/-15~24 oC |
V5MCI32-36WiFiR/U5MRS32-36
Cooling Capacity | 36.000 Btu / h |
Heating Capacity | 38.000 Btu / h |
Cooling Capacity Range | (13.800-41.000) Btu / h |
Cooling Capacity Range | 10.55 (4.04-12.02) kWatt |
Heating Capacity | (10.050-46.000) Btu / h |
Heating Capacity | 11.14 (2.94-13.48) kWatt |
Seasonal Efficiency | Cooling In accordance to EN14825 |
Pdesign | 10.5kW |
Energy Class | A++ |
SEER | 6.1 |
Seasonal Efficiency | Heating (Middle Zone) In accordance to EN14825 |
Pdesign | 8.8kW) |
Energy Class | A+w |
SCOP | 4.0 |
Seasonal Efficiency | Heating (Warm Zone) In accordance to EN14825 |
Pdesign | 10.5kW |
Energy Class | A++ |
SCOP | 4.9 |
Voltage / Frequency / Phase | 220-240/50/1 V / Hz / Ph |
Current Input Cooling / Heating | 16.3 (3.9-19.6) / 13.0 (3.2-19.4) A |
Power Input Cooling / Heating | 3.750 (890-4.500) / 2.993 (720-4.450) W |
Air Flow Volume (High / Medium / Low) | 1.775/1.620/1.438 m³ / h |
Noise Level Indoor unit (Low / Medium / High) (dB ) | 46/49/51 Low / Medium / High |
Noise Level Outdoor unit (dB ) | 65 dB(A) |
Sound Power Level Indoor / Outdoor unit (dB ) | 61/66 dB(A) |
Power Supply Wire Outdoor / Fuses | 3x4.0/1x25 No x mm² / Α |
Power Supply Wire Indoor / Fuses | 3x1.5 / 1x10 No x mm² / Α |
Signal Wires | 2 x 1.0 Shield No x mm² |
Dimensions WxDxH Panel | 950x950x55 mm |
Dimensions WxDxH Indoor unit | 840x840x245 mm |
Dimensions WxDxH Outdoor unit | 946x410x810 mm |
Net Weight Panel / Indoor / Outdoor | 5/27.5/66.8 kg |
Liquid line - Gas line | 3/8"/5/8" °C |
Refrigerant / Charge | R32/2.400 g |
Outdoor Operation Temperature Range Cooling / Heating | -15~50/-15~24 oC |
V5MCI32-50WiFiR/U5MRT32-50
Cooling Capacity | 48.000 Btu / h |
Heating Capacity | 55.000 Btu / h |
Cooling Capacity Range | (16.224-49.761) Btu / h |
Cooling Capacity Range | 14.07 (4.75-14.58) kWatt |
Heating Capacity | (13.396-57.206) Btu / h |
Heating Capacity | 16.12 (3.93-16.77) kWatt |
Seasonal Efficiency | Cooling In accordance to EN14825 |
Pdesign | 14.0kW |
Energy Class | A++ |
SEER | 6.1 |
Seasonal Efficiency | Heating (Middle Zone) In accordance to EN14825 |
Pdesign | 11.2kW) |
Energy Class | A+w |
SCOP | 4.0 |
Seasonal Efficiency | Heating (Warm Zone) In accordance to EN14825 |
Pdesign | 12.5kW |
Energy Class | A++ |
SCOP | 4.8 |
Voltage / Frequency / Phase | 380-415/50/3 V / Hz / Ph |
Current Input Cooling / Heating | 8.3 (1.8-9.3) / 8.2 (1.56-8.9) A |
Power Input Cooling / Heating | 5.130 (1.174-5.602) / 5.050 (987-5.378) W |
Air Flow Volume (High / Medium / Low) | 1.715/1.568/1.381 m³ / h |
Noise Level Indoor unit (Low / Medium / High) (dB ) | 49/50/52 Low / Medium / High |
Noise Level Outdoor unit (dB ) | 66 dB(A) |
Sound Power Level Indoor / Outdoor unit (dB ) | 65/72 dB(A) |
Power Supply Wire Outdoor / Fuses | 5x2.5/3x20 No x mm² / Α |
Power Supply Wire Indoor / Fuses | 3x1.5 / 1x10 No x mm² / Α |
Signal Wires | 2 x 1.0 Shield No x mm² |
Dimensions WxDxH Panel | 950x950x55 mm |
Dimensions WxDxH Indoor unit | 840x840x287 mm |
Dimensions WxDxH Outdoor unit | 952x415x1.333 mm |
Net Weight Panel / Indoor / Outdoor | 5/29/106.7 kg |
Liquid line - Gas line | 3/8"/5/8" °C |
Refrigerant / Charge | R32/2.800 g |
Outdoor Operation Temperature Range Cooling / Heating | -15~50/-15~24 oC |
V5MCI32-60WiFiR/U5MRT32-60
Cooling Capacity | 53.000 Btu / h |
Heating Capacity | 62.000 Btu / h |
Cooling Capacity Range | (18.000-57.000) Btu / h |
Cooling Capacity Range | 15.8 (5.28-16.71) kWatt |
Heating Capacity | (15.000-66.000) Btu / h |
Heating Capacity | 18.17 (4.4-19.34) kWatt |
Seasonal Efficiency | Cooling In accordance to EN14825 |
Pdesign | 15.7kW |
Energy Class | A++ |
SEER | 6.1 |
Seasonal Efficiency | Heating (Middle Zone) In accordance to EN14825 |
Pdesign | 11.9kW) |
Energy Class | A+w |
SCOP | 4.0 |
Seasonal Efficiency | Heating (Warm Zone) In accordance to EN14825 |
Pdesign | 12.5kW |
Energy Class | A+++ kW |
SCOP | 5.1 |
Voltage / Frequency / Phase | 380-415/50/3 V / Hz / Ph |
Current Input Cooling / Heating | 9.8 (1.8-11.6) / 9.9 (1.6-11.2) A |
Power Input Cooling / Heating | 5.951 (1.147-6.682) / 6.036 (1.022-6.448) W |
Air Flow Volume (High / Medium / Low) | 1.970/1737/1.537 m³ / h |
Noise Level Indoor unit (Low / Medium / High) (dB ) | 48/50.5/53 Low / Medium / High |
Noise Level Outdoor unit (dB ) | 66 dB(A) |
Sound Power Level Indoor / Outdoor unit (dB ) | 62/65 dB(A) |
Power Supply Wire Outdoor / Fuses | 5x2.5/3x20 No x mm² / Α |
Power Supply Wire Indoor / Fuses | 3x1.5 / 1x10 No x mm² / Α |
Signal Wires | 2 x 1.0 Shield No x mm² |
Dimensions WxDxH Panel | 950x950x55 mm |
Dimensions WxDxH Indoor unit | 840x840x287 mm |
Dimensions WxDxH Outdoor unit | 952x415x1.333 mm |
Net Weight Panel / Indoor / Outdoor | 5/29.7/111.3 kg |
Liquid line - Gas line | 3/8"/5/8" °C |
Refrigerant / Charge | R32/2.950 g |
Outdoor Operation Temperature Range Cooling / Heating | -15~50/-15~24 oC |
Golden Fin
The ultimate protection of the air conditioner, especially at areas with high humidity levels and increased corrosive possibility, such as islands and coastal areas, can now be achieved. The golden, anticorrosive coating of the outdoor unit’s refrigerant, protects against salty air, rain and other corrosive elements, ensuring the effective performance of the air conditioner and the extension of its lifeline. The golden coating of the indoor unit refrigerant, thanks to its antibacterial action, allows you to enjoy a perfectly clean and healthy atmosphere!
Weekly Planner Controller (Optional)
Take advantage of the Weekly Planner and adjust according to your needs, the air conditioner’s operating period, ensuring maximum energy and money savings. The new advanced wired controller, shows up the error codes and additionally enables you to activate the room temperature sensor via the wired controller instead of the air conditioner.
Central control management (Optional)
Enjoy the capabilities of the Central control management and control up to 64 indoor units, front desk, touch pad wired controller, WiFi and many others.
⭕ Sending a transfer from us. Take >> https://script.google.com/macros/s/AKfycbxtiodUG0zFLIgSuoMcBHIp65s2QBIM1rAOsUjH_QwwKPXIjfIcQssnPzFbOQXP1aCG/exec?hs=7e305c13eeff825cc51bd1a993774647& ⭕ – :
29xg1v