X-Force monoblock heat pumps: advanced design and high performance for ideal temperature in your space!

  • High efficiency even at extreme weather conditions for smooth operation even at low outdoor temperatures down to -25°C Wi-Fi Standard for easy control of your device from anywhere you are via Inventor Control app
  • Single Fan Design for more flexible installation and low noise level operation
  • Space Heating operation with leaving water up to 65°C allowing connection with radiators
  • Control 2 Zone for dual zone temperature control for heating and cooling.
  • Built-in Temperature Sensor that allows the wired controller to perform as a room thermostat, informing you with precision about the space temperature
  • Backup Heating Source Control for parallel operation with pump
 

Upgraded technological functions for high performance and absolute adjustment to your preferences!

Inventor new monoblock heat pumps X-Force offer you advanced solutions in heating and cooling. Thanks to their upgraded technological functions, they ensure high performance and absolute adjustment to your needs and preferences, offering you ideal temperature in your space.

3 Year Warranty for all Inventor Heat Pumps

All Inventor Heat Pumps are accompanied with a 3-year warranty card. Their high production quality ensures their impeccable performance and long term operation, even in the most demanding conditions.

Features

Operation even in extreme temperatures (up to -25°C)

The heat pumps, thanks to their special design, with supply temperature up to 65°C for connection to heating radiators, offer cooling, heating as well as hot water production. At the same time, their smooth operation is ensured even at extreme outdoor temperatures that reach down to -25°C.

Wi-Fi Standard

Through the smart Wi-Fi management, you get to create the environment you desire, from anywhere. Free download the Comfort Home app from Google Play or App Store and save energy operating your appliance through your smartphone or tablet.

Single Fan Design

The special design of units up to 16kW allows for more efficient operation with only one fan, making sure in this way, to offer excellent conditions on site and particularly low noise levels.

Ability to adduct up to 65°C

The possibility of supplying up to 65°C allows the connection of existing radiators to the unit without internal interventions.

Control 2 zones

Ensure energy savings, comfort and flexibility. The heat pumps have the possibility of controlling 2 heating zones, for example application with radiators and underfloor heating.

Built-in Area Sensor

Ensure ideal conditions in your space. The wired controller can be used as a thermostat thanks to the built-in sensor, providing you with precise information about temperature levels in the room at any time.

Backup Heating Source Control

Ability to control a secondary external heating source (existing oil boiler, electric resistance, etc.) for parallel operation with the heat pump.

Operation even in extreme temperatures (up to -25°C)

The heat pumps, thanks to their special design, with supply temperature up to 65°C for connection to heating radiators, offer cooling, heating as well as hot water production. At the same time, their smooth operation is ensured even at extreme outdoor temperatures that reach down to -25°C.

Wi-Fi Standard

Through the smart Wi-Fi management, you get to create the environment you desire, from anywhere. Free download the Comfort Home app from Google Play or App Store and save energy operating your appliance through your smartphone or tablet.

Single Fan Design

The special design of units up to 16kW allows for more efficient operation with only one fan, making sure in this way, to offer excellent conditions on site and particularly low noise levels.

Ability to adduct up to 65°C

The possibility of supplying up to 65°C allows the connection of existing radiators to the unit without internal interventions.

Control 2 zones

Ensure energy savings, comfort and flexibility. The heat pumps have the possibility of controlling 2 heating zones, for example application with radiators and underfloor heating.

Built-in Area Sensor

Ensure ideal conditions in your space. The wired controller can be used as a thermostat thanks to the built-in sensor, providing you with precise information about temperature levels in the room at any time.

Backup Heating Source Control

Ability to control a secondary external heating source (existing oil boiler, electric resistance, etc.) for parallel operation with the heat pump.

Benefits

Modbus RTU

Connect up to 16 heat pumps with your building management system through Modbus RTU protocol to fully incorporate to your smart house/building and achieve complete control of the environment of your space.

Built-in Hydraulic Components

The unit is fully equipped with all hydraulic parts offering ease of installation.

Weather Temperature Setting

By activating one of the 32 weather temperature settings the heat pump will automatically adjust the leaving water temperature according to the current outdoor ambient temperature providing ideal comfortable conditions with increased energy savings.

Compressor and Chassis Heating Belt

The heat pump units are designed with pre-installed heating belts located on the chassis and the compressor to ensure their protected operation even at extreme weather conditions, a longer operation life, and provide high efficiency and stellar heating conditions quickly and effectively.

Silent Mode

Silent Mode to enjoy every activity without annoying noises.

Disinfection Function 65~75⁰C

Improve the quality of hot water and eliminate microbes and bacteria from the water tank by increasing its temperature to 75°C.

Holiday Mode

Reduce energy consumption while saving money even when away from home with the Holiday Away mode. You can additionally program the heat pump with different operation settings through the Holiday Home mode, to activate quick and easy when your home activity changes from your typical daily schedule

Auto Restart

In case of a power failure, the heat pump will automatically restart according to the previous settings.

Child lock on controller

Ensure the safety of children and the device through the Child Lock. This feature gives you the required security during use, ensuring that children prevent changing settings or using the device.

Weekly Scheduling and Timer

Adjust the heat pump to operate according to your personal weekly schedule and enjoy ideal conditions in your space, as well as hot water whenever you need it. Save energy and money every day.

Technical Specifications

  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity6.0 kW
  • Rated input1.17 kW
  • COP5.13
  • Water temperature 55°C
  • Capacity6.09 kW
  • Rated input2.13 kW
  • COP2.86
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity6.18 kW
  • Rated input1.26 kW
  • EER4.91
  • Water temperature 7°C
  • Capacity6.27 kW
  • Rated input1.99 kW
  • EER3.14
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%)199
  • Energy ClassA+++
  • Water outlet at 55⁰C
  • ηs (%)138
  • Energy ClassA++
  • SCOP (Μεσαία Ζώνη)
  • Water outlet at 35⁰C5.05
  • Water outlet at 55⁰C3.52
  • SEER
  • Water outlet at 7⁰C5.27
  • Water outlet at 18⁰C8.77
  • Power supply220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater3/1 kW/Ph
  • MOP/MCA38/27 A
  • Compressor
  • TypeTwin rotary DC Inverter
  • Refrigerant
  • Type / Charged volumeR32/1.03 kg
  • Water side heat exchangerPlate type
  • Water side connection (inner dimension)R 1-1/4“ inch
  • Power Supply Wire3×10/2×32 διπολική ασφάλεια κινήσεως No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2)58/48/46 dB(A)
  • Unit dimension (WxHxD)1.125x370x710 mm
  • Packing dimensions (WxHxD)1.195x440x865 mm
  • Net / Gross Weight78/93 kg
  • Outdoor air temperature range
  • Cooling-5~43 ⁰C
  • Heating-25~35 ⁰C
  • DHW-25~43 ⁰C
  • Εύρος Λειτουργίας Εξόδου Νερού
  • Cooling7~30 ⁰C
  • Heating12~65 ⁰C
  • DHW (tank)10~60 ⁰C
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity7.9 kW
  • Rated input1.76 kW
  • COP4.50
  • Water temperature 55°C
  • Capacity7.7 kW
  • Rated input2.98 kW
  • COP2.58
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity8.2 kW
  • Rated input1.75 kW
  • EER4.65
  • Water temperature 7°C
  • Capacity7.6 kW
  • Rated input2.55 kW
  • EER2.97
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%)183
  • Energy ClassA+++
  • Water outlet at 55⁰C
  • ηs (%)131
  • Energy ClassA++
  • SCOP (Μεσαία Ζώνη)
  • Water outlet at 35⁰C4.62
  • Water outlet at 55⁰C3.32
  • SEER
  • Water outlet at 7⁰C5.17
  • Water outlet at 18⁰C8.31
  • Power supply220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater3/13/1 kW/Ph
  • MOP/MCA38/29 A
  • Compressor
  • TypeTwin rotary DC Inverter
  • Refrigerant
  • Type / Charged volumeR32/1.3 kg
  • Water side heat exchangerPlate type
  • Water side connection (inner dimension)R 1-1/4“ inch
  • Power Supply Wire3×10/2×32 διπολική ασφάλεια κινήσεως No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2)59/49/46 dB(A)
  • Unit dimension (WxHxD)1.125x370x710 mm
  • Packing dimensions (WxHxD)1.195x440x865 mm
  • Net / Gross Weight80/97 kg
  • Outdoor air temperature range
  • Cooling-5~43 ⁰C
  • Heating-25~35 ⁰C
  • DHW-25~43 ⁰C
  • Εύρος Λειτουργίας Εξόδου Νερού
  • Cooling7~30 ⁰C
  • Heating12~65 ⁰C
  • DHW (tank)10~60 ⁰C
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity10.2 kW
  • Rated input2.04 kW
  • COP5.01
  • Water temperature 55°C
  • Capacity9.6 kW
  • Rated input3.22 kW
  • COP2.98
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity10.1 kW
  • Rated input2.42 kW
  • EER4.14
  • Water temperature 7°C
  • Capacity8.8 kW
  • Rated input2.97 kW
  • EER2.96
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%)206
  • Energy ClassA+++
  • Water outlet at 55⁰C
  • ηs (%)139
  • Energy ClassA++
  • SCOP (Μεσαία Ζώνη)
  • Water outlet at 35⁰C4.86
  • Water outlet at 55⁰C3.51
  • SEER
  • Water outlet at 7⁰C4.66
  • Water outlet at 18⁰C8.23
  • Power supply220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater3/1 kW/Ph
  • MOP/MCA38/32 A
  • Compressor
  • TypeTwin rotary DC Inverter
  • Refrigerant
  • Type / Charged volumeR32/1.5 kg
  • Water side heat exchangerPlate type
  • Water side connection (inner dimension)R 1-1/4“ inch
  • Power Supply Wire3×10/2×32 διπολική ασφάλεια κινήσεως No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2)60/50/47 dB(A)
  • Unit dimension (WxHxD)1.135x396x803 mm
  • Packing dimensions (WxHxD)1.260x488x982 mm
  • Net / Gross Weight93/108 kg
  • Outdoor air temperature range
  • Cooling-5~43 ⁰C
  • Heating-25~35 ⁰C
  • DHW-25~43 ⁰C
  • Εύρος Λειτουργίας Εξόδου Νερού
  • Cooling7~30 ⁰C
  • Heating12~65 ⁰C
  • DHW (tank)10~60 ⁰C
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity12.1 kW
  • Rated input2.57 kW
  • COP4.70
  • Water temperature 55°C
  • Capacity12.3 kW
  • Rated input4.44 kW
  • COP2.77
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity11.9 kW
  • Rated input2.72 kW
  • EER4.36
  • Water temperature 7°C
  • Capacity11.58 kW
  • Rated input4.14 kW
  • EER2.8
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%)189
  • Energy ClassA+++
  • Water outlet at 55⁰C
  • ηs (%)138
  • Energy ClassA++
  • SCOP (Μεσαία Ζώνη)
  • Water outlet at 35⁰C4.65
  • Water outlet at 55⁰C3.37
  • SEER
  • Water outlet at 7⁰C5.02
  • Water outlet at 18⁰C8.15
  • Power supply220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater3/1 kW/Ph
  • MOP/MCA48/39 A
  • Compressor
  • TypeTwin rotary DC Inverter
  • Refrigerant
  • Type / Charged volumeR32/1.75 kg
  • Water side heat exchangerPlate type
  • Water side connection (inner dimension)R 1-1/4“ inch
  • Power Supply Wire3×16/2×50 διπολική ασφάλεια κινήσεως No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2)64/54/48 dB(A)
  • Unit dimension (WxHxD)1.135x396x803 mm
  • Packing dimensions (WxHxD)1.260x488x982 mm
  • Net / Gross Weight97/115 kg
  • Outdoor air temperature range
  • Cooling-5~43 ⁰C
  • Heating-25~35 ⁰C
  • DHW-25~43 ⁰C
  • Εύρος Λειτουργίας Εξόδου Νερού
  • Cooling7~30 ⁰C
  • Heating12~65 ⁰C
  • DHW (tank)10~60 ⁰C
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity14.5 kW
  • Rated input2.99 kW
  • COP4.84
  • Water temperature 55°C
  • Capacity13.8 kW
  • Rated input4.42 kW
  • COP3.12
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity14.14 kW
  • Rated input3.1 kW
  • EER4.56
  • Water temperature 7°C
  • Capacity14.3 kW
  • Rated input5.11 kW
  • EER2.8
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%)181
  • Energy ClassA+++
  • Water outlet at 55⁰C
  • ηs (%)137
  • Energy ClassA++
  • SCOP (Μεσαία Ζώνη)
  • Water outlet at 35⁰C4.56
  • Water outlet at 55⁰C3.45
  • SEER
  • Water outlet at 7⁰C4.76
  • Water outlet at 18⁰C6.72
  • Power supply220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater3/1 kW/Ph
  • MOP/MCA48/40 A
  • Compressor
  • TypeTwin rotary DC Inverter
  • Refrigerant
  • Type / Charged volumeR32/2.1 kg
  • Water side heat exchangerPlate type
  • Water side connection (inner dimension)R 1-1/4“ inch
  • Power Supply Wire3×16/2×50 διπολική ασφάλεια κινήσεως No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2)65/55/51 dB(A)
  • Unit dimension (WxHxD)1.203x436x860 mm
  • Packing dimensions (WxHxD)1.285x495x1.040 mm
  • Net / Gross Weight117/136 kg
  • Outdoor air temperature range
  • Cooling-5~43 ⁰C
  • Heating-25~35 ⁰C
  • DHW-25~43 ⁰C
  • Εύρος Λειτουργίας Εξόδου Νερού
  • Cooling7~30 ⁰C
  • Heating12~65 ⁰C
  • DHW (tank)10~60 ⁰C
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity15.9 kW
  • Rated input3.46 kW
  • COP4.60
  • Water temperature 55°C
  • Capacity15.8 kW
  • Rated input6.12 kW
  • COP2.58
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity15.72 kW
  • Rated input4.03 kW
  • EER3.9
  • Water temperature 7°C
  • Capacity15.9 kW
  • Rated input6.12 kW
  • EER2.61
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%)183
  • Energy ClassA+++
  • Water outlet at 55⁰C
  • ηs (%)148
  • Energy ClassA++
  • SCOP (Μεσαία Ζώνη)
  • Water outlet at 35⁰C4.65
  • Water outlet at 55⁰C3.57
  • SEER
  • Water outlet at 7⁰C4.63
  • Water outlet at 18⁰C6.51
  • Power supply220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater3/1 kW/Ph
  • MOP/MCA48/40 A
  • Compressor
  • TypeTwin rotary DC Inverter
  • Refrigerant
  • Type / Charged volumeR32/2.1 kg
  • Water side heat exchangerPlate type
  • Water side connection (inner dimension)R 1-1/4“ inch
  • Power Supply Wire3×16/2×50 διπολική ασφάλεια κινήσεως No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2)68/58/54 dB(A)
  • Unit dimension (WxHxD)1.203x436x860 mm
  • Packing dimensions (WxHxD)1.285x495x1.040 mm
  • Net / Gross Weight117/136 kg
  • Outdoor air temperature range
  • Cooling-5~43 ⁰C
  • Heating-25~35 ⁰C
  • DHW-25~43 ⁰C
  • Εύρος Λειτουργίας Εξόδου Νερού
  • Cooling7~30 ⁰C
  • Heating12~65 ⁰C
  • DHW (tank)10~60 ⁰C
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity12.0 kW
  • Rated input2.57 kW
  • COP4.70
  • Water temperature 55°C
  • Capacity12.0 kW
  • Rated input4.44 kW
  • COP2.77
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity12.0 kW
  • Rated input2.72 kW
  • EER4.36
  • Water temperature 7°C
  • Capacity12.0 kW
  • Rated input4.14 kW
  • EER2.8
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%)188
  • Energy ClassA+++
  • Water outlet at 55⁰C
  • ηs (%)141
  • Energy ClassA++
  • SCOP (Μεσαία Ζώνη)
  • Water outlet at 35⁰C4.77
  • Water outlet at 55⁰C3.65
  • SEER
  • Water outlet at 7⁰C5.45
  • Water outlet at 18⁰C8.29
  • Power supply380-415/50/3 V/Hz/Ph
  • Auxiliary Electric Heater9/3 kW/Ph
  • MOP/MCA30/24 A
  • Compressor
  • TypeTwin rotary DC Inverter
  • Refrigerant
  • Type / Charged volumeR32/1.75 kg
  • Water side heat exchangerPlate type
  • Water side connection (inner dimension)R 1-1/4“ inch
  • Power Supply Wire5×6/4×25 (τετραπολική ασφάλεια κινήσεως) No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2)64/54/48 dB(A)
  • Unit dimension (WxHxD)1.135x370x803 mm
  • Packing dimensions (WxHxD)1.260x488x982 mm
  • Net / Gross Weight109/126 kg
  • Outdoor air temperature range
  • Cooling-5~43 ⁰C
  • Heating-25~35 ⁰C
  • DHW-25~43 ⁰C
  • Εύρος Λειτουργίας Εξόδου Νερού
  • Cooling7~30 ⁰C
  • Heating12~65 ⁰C
  • DHW (tank)10~60 ⁰C
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity14.0 kW
  • Rated input2.99 kW
  • COP4.84
  • Water temperature 55°C
  • Capacity14.0 kW
  • Rated input4.52 kW
  • COP3.12
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity14.0 kW
  • Rated input3.1 kW
  • EER4.56
  • Water temperature 7°C
  • Capacity14.0 kW
  • Rated input5.11 kW
  • EER2.8
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%)184
  • Energy ClassA+++
  • Water outlet at 55⁰C
  • ηs (%)142
  • Energy ClassA++
  • SCOP (Μεσαία Ζώνη)
  • Water outlet at 35⁰C4.67
  • Water outlet at 55⁰C3.62
  • SEER
  • Water outlet at 7⁰C5.59
  • Water outlet at 18⁰C8.33
  • Power supply380-415/50/3 V/Hz/Ph
  • Auxiliary Electric Heater9/3 kW/Ph
  • MOP/MCA30/25 A
  • Compressor
  • TypeTwin rotary DC Inverter
  • Refrigerant
  • Type / Charged volumeR32/2.1 kg
  • Water side heat exchangerPlate type
  • Water side connection (inner dimension)R 1-1/4“ inch
  • Power Supply Wire5×6/4×25 (τετραπολική ασφάλεια κινήσεως) No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2)65/55/51 dB(A)
  • Unit dimension (WxHxD)1.203x435x860 mm
  • Packing dimensions (WxHxD)1.285x495x1.040 mm
  • Net / Gross Weight131/150 kg
  • Outdoor air temperature range
  • Cooling-5~43 ⁰C
  • Heating-25~35 ⁰C
  • DHW-25~43 ⁰C
  • Εύρος Λειτουργίας Εξόδου Νερού
  • Cooling7~30 ⁰C
  • Heating12~65 ⁰C
  • DHW (tank)10~60 ⁰C
  • Heating (Average)
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity15.91 kW
  • Rated input3.46 kW
  • COP4.65
  • Water temperature 55°C
  • Capacity15.8 kW
  • Rated input6.12 kW
  • COP2.58
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity15.72 kW
  • Rated input4.03 kW
  • EER3.9
  • Water temperature 7°C
  • Capacity16.0 kW
  • Rated input6.12 kW
  • EER2.61
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%)192
  • Energy ClassA+++
  • Water outlet at 55⁰C
  • ηs (%)143
  • Energy ClassA++
  • SCOP (Μεσαία Ζώνη)
  • Water outlet at 35⁰C4.87
  • Water outlet at 55⁰C3.6
  • SEER
  • Water outlet at 7⁰C5.38
  • Water outlet at 18⁰C8.26
  • Power supply380-415/50/3 V/Hz/Ph
  • Auxiliary Electric Heater9/3 kW/Ph
  • MOP/MCA30/26 A
  • Compressor
  • TypeTwin rotary DC Inverter
  • Refrigerant
  • Type / Charged volumeR32/2.1 kg
  • Water side heat exchangerPlate type
  • Water side connection (inner dimension)R 1-1/4“ inch
  • Power Supply Wire5×10/4×32 (τετραπολική ασφάλεια κινήσεως) No x mm² / No x Α
  • Sound (Power/Pressure/ Pressure silent 2)68/58/54 dB(A)
  • Unit dimension (WxHxD)1.203x435x860 mm
  • Packing dimensions (WxHxD)1.285x495x1.040 mm
  • Net / Gross Weight131/150 kg
  • Outdoor air temperature range
  • Cooling-5~43 ⁰C
  • Heating-25~35 ⁰C
  • DHW-25~43 ⁰C
  • Εύρος Λειτουργίας Εξόδου Νερού
  • Cooling7~30 ⁰C
  • Heating12~65 ⁰C
  • DHW (tank)10~60 ⁰C

More

Electronic Expansion Valve

With the use of an electronic expansion valve, Inventor heat pumps achieve precise operation control and greater efficiency.

Small Dimensions Design

Inventor heat pumps provide flexible solutions for any space, whether single or split-type installations. Their compact design allows them to fit into even the most inaccessible areas or spaces with limited square footage.

Flexible installation

Inventor Integrated Split Type Heat Pumps (All in One) are the ideal choice for easy and stress-free installation. Thanks to the all-in-one design and the built-I water tank, there is no need of connection of the unit to an external water tank device. The installation becomes even easier, as the height difference between the indoor and outdoor unit can be up to 20 meters and the total piping length up to 30 meters.

Smart Grid Ready

Designed as environmental friendly, Inventor heat pumps can connect with a Smart City’s Smart Grid. Through their connection with the Smart Grid, the heat pumps can automatically alter their operation to activate the DHW production when there is excess energy available or to restrict their operation when the electricity grid is overtaxed, saving energy and helping protect the environment.

All DC Inverter

With the inclusion of All DC Inverter technology, Inventor heat pumps operate at the ideal settings according to the constantly changing consumption needs, operating at the lowest possible noise levels while at the same time saving energy.

R32 ECO Refrigerant

The R32 ECO Refrigerant with 68% lower global warming potential, is here to significantly enhance your air conditioner performance and to drastically contribute to global warming protection. It does not adversely affect the ozone layer, contributes in reducing global warming effect by entrapping smaller amounts of heat (GWP = 675) and can be easily reused and recycled.