Matrix Split Type heat pumps for high performance, energy saving & ultimate comfort!

  • Energy class A+++ for saving energy and money with excellent performance
  • Excellent operation even in extreme outdoor temperatures
  • Inlet water up to 65°C for connection of radiators
  • Complete Central Control with simple usage due to the touch control of your device, featuring a Multilanguage Menu with various functions
  • Set up the device via Wi-Fi
  • Equipped with anti-icing bottom base resistor on the outdoor unit for operation at low temperatures
  • Two levels of quiet operation for reduced noise

All-in-One design for total comfort, flexibility, and guaranteed performance!

Inventor Integrated Split Type Heat Pumps (All in One) offer a complete solution for your home, as they have an integrated water tank to produce domestic hot water (DHW), offering you flexibility and a guaranteed result.

In addition, they are the ideal solution for heating and cooling, covering all the needs of your space such as floor heating and cooling, space heating with radiators, cooling and heating with fan coils.

3 Year Warranty for all Inventor Heat Pumps

All Inventor Heat Pumps are accompanied with a 3-year warranty card. Their high production quality ensures their impeccable performance and long term operation, even in the most demanding conditions.

Features

Flexible installation

Inventor Integrated Split Type Heat Pumps (All in One) are the ideal choice for easy and stress-free installation. Thanks to the all-in-one design and the built-I water tank, there is no need of connection of the unit to an external water tank device. The installation becomes even easier, as the height difference between the indoor and outdoor unit can be up to 20 meters and the total piping length up to 30 meters.

Complete Solution

Inventor Integrated Split Type Heat Pumps (All in One) are a complete solution for every home as they include a water tank. Therefore, there is no need of purchasing an extra device. In this way, you have two in one device, saving space and time as you don’t have to find another device.

Ready-to-use system for guaranteed results

The right solution for the best results. The All-in-One design of the indoor units includes a water tank, so that there is no need to purchase and connect an extra water tank. Therefore, you avoid compatibility issues when connecting the external water tank. Ensure a guaranteed result and the production of domestic hot water (DHW).

Built-in indoor unit

The design of built-in indoor unit ensures an elegant result inside your home, upgrading your kitchen while giving you the comfort that you need.

Α+++ Energy Class

The technological superiority of Inventor heat pumps guarantees impeccable performance with the smallest functional cost. Benefit from the highest energy class of A+++ (heating – warm zone) and save energy, creating the atmosphere you desire.

Operation even in extreme temperatures (up to -25°C)

The heat pumps, thanks to their special design, with supply temperature up to 65°C for connection to heating radiators, offer cooling, heating as well as hot water production. At the same time, their smooth operation is ensured even at extreme outdoor temperatures that reach down to -25°C.

Ultimate Central Control

The heat pumps are equipped with a touch wired controller for an even easier usage of your appliance, offering access to an important number of functions.

Flexible installation

Inventor Integrated Split Type Heat Pumps (All in One) are the ideal choice for easy and stress-free installation. Thanks to the all-in-one design and the built-I water tank, there is no need of connection of the unit to an external water tank device.

The installation becomes even easier, as the height difference between the indoor and outdoor unit can be up to 20 meters and the total piping length up to 30 meters.

Complete Solution

Inventor Integrated Split Type Heat Pumps (All in One) are a complete solution for every home as they include a water tank. Therefore, there is no need of purchasing an extra device. In this way, you have two in one device, saving space and time as you don’t have to find another device.

Ready-to-use system for guaranteed results

The right solution for the best results. The All-in-One design of the indoor units includes a water tank, so that there is no need to purchase and connect an extra water tank. Therefore, you avoid compatibility issues when connecting the external water tank. Ensure a guaranteed result and the production of domestic hot water (DHW).

Built-in indoor unit

The design of built-in indoor unit ensures an elegant result inside your home, upgrading your kitchen while giving you the comfort that you need.

A+++ Energy Class

The technological superiority of Inventor heat pumps guarantees excellent performance with the lowest functional cost. Benefit from the highest energy class A+++ (heating – warm zone) and save energy while creating the desired conditions.

Operation even in extreme temperatures (up to -25°C)

The heat pumps, thanks to their special design, with supply temperature up to 65°C for connection to heating radiators, offer cooling, heating as well as hot water production. At the same time, their smooth operation is ensured even at extreme outdoor temperatures that reach down to -25°C.

Ultimate Central Control

The heat pumps are equipped with a touch wired controller for an even easier usage of your appliance, offering access to an important number of functions.
• Set the heat pump to operate according to your weekly schedule and enjoy ideal conditions in your space and availability of DHW when in need, saving energy and money on a daily basis, thanks to the Weekly Timer.
• Activate the Eco function and reduce the power consumption saving energy and money.
• Reduce energy consumption while saving money even when away from home with the Holiday Away mode. You can additionally program the heat pump with different operation settings through the Holiday Home mode, to activate quick and easy when your home activity changes from your typical daily schedule.
• Achieve ideal conditions in your space by using the wired controller as an external thermostat. The built-in temperature sensor will provide accurate room temperature information to the heat pump, for increased comfort.

Benefits

Wi-Fi Standard

Through the smart Wi-Fi management, you get to create the environment you desire, from anywhere. Free download the Comfort Home app from Google Play or App Store and save energy operating your appliance through your smartphone or tablet.

Compressor and Chassis Heating Belt

The heat pump units are designed with pre-installed heating belts located on the chassis and the compressor to ensure their protected operation even at extreme weather conditions, a longer operation life, and provide high efficiency and stellar heating conditions quickly and effectively.

2 Stage Silent Mode

Reduce the heat pump noise levels even further by selecting between the two different levels of silent operation.

Disinfection Function 65~70⁰C

Maintain pristine quality of the water tank’s DHW and eliminate germs and bacteria by increasing the temperature of the water in it up to 70⁰C.

Fast Domestic Hot Water Function

You can select the Fast DHW Function for the unit to produce DHW when there is a need for immediate hot water production.

All DC Inverter

With the inclusion of All DC Inverter technology, Inventor heat pumps operate at the ideal settings according to the constantly changing consumption needs, operating at the lowest possible noise levels while at the same time saving energy.

Backup Heating Source Control

Ability to control a secondary external heating source (existing oil boiler, electric resistance, etc.) for parallel operation with the heat pump.

Smart Grid Ready

Designed as environmental friendly, Inventor heat pumps can connect with a Smart City’s Smart Grid. Through their connection with the Smart Grid, the heat pumps can automatically alter their operation to activate the DHW production when there is excess energy available or to restrict their operation when the electricity grid is overtaxed, saving energy and helping protect the environment.

Underfloor drying operation

Protect your home's floor thanks to the underfloor drying function, which can gradually increase the underfloor heating temperature to avoid damage to the floor and for a smoother transition to heating mode. The Floor Drying Up function is an additional solution for the installer, as it helps to remove any residual moisture that may occur when installing new underfloor heating circuits, thus protecting the new installation and ensuring better and more efficient use of the heat pump.

Technical Specifications

  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity4.25 kW
  • Rated input0.82 kW
  • COP5.20
  • Water temperature 55°C
  • Capacity4.4 kW
  • Rated input1.49 kW
  • COP2.95
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity4.5 kW
  • Rated input0.81 kW
  • EER5.55
  • Water temperature 7°C
  • Capacity4.7 kW
  • Rated input1.36 kW
  • EER3.45
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%)191
  • classA+++
  • Water outlet at 55⁰C
  • ηs (%)129.5
  • classA++
  • SCOP (Average)
  • Water outlet at 35⁰C4.85
  • Water outlet at 55⁰C3.31
  • SEER
  • Water outlet at 7⁰C4.98
  • Water outlet at 18⁰C7.77
  • Power supply220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater3/1 kW/Ph
  • MOP/MCA18/12 A
  • Compressor
  • TipoTwin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.50 kg
  • Water side heat exchangerPlate type
  • Pipe size
  • Liquid | Gas | Water1/4 | 5/8 | R1 inch
  • Power Supply Wire Indoor3×4.0 / 2×20 (bipolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire Outdoor3×4.0 / 2×20 (bipolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire3×1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor56/44/39 dB(A)
  • Indoor38/22 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor1.008x712x426 mm
  • Indoor600×1.683×600 mm
  • Net weight Outdoor/Indoor58/140 kg
  • Domestic Hot Water Tank
  • Volume190 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure10 bar
  • MaterialStainless Steel
  • Outdoor air temperature range
  • Cooling-5~43 ⁰C
  • Heating-25~35 ⁰C
  • DHW-25~43 ⁰C
  • Water outlet temperature range
  • Cooling5~25 ⁰C
  • Heating25~65 ⁰C
  • DHW (tank)30~60 ⁰C
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity4.25 kW
  • Rated input0.82 kW
  • COP5.20
  • Water temperature 55°C
  • Capacity4.4 kW
  • Rated input1.49 kW
  • COP2.95
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity4.5 kW
  • Rated input0.81 kW
  • EER5.55
  • Water temperature 7°C
  • Capacity4.7 kW
  • Rated input1.36 kW
  • EER3.45
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%)191
  • classA+++
  • Water outlet at 55⁰C
  • ηs (%)129.5
  • classA++
  • SCOP (Average)
  • Water outlet at 35⁰C4.85
  • Water outlet at 55⁰C3.31
  • SEER
  • Water outlet at 7⁰C4.98
  • Water outlet at 18⁰C7.77
  • Power supply220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater3/1 kW/Ph
  • MOP/MCA18/12 A
  • Compressor
  • TipoTwin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.50 kg
  • Water side heat exchangerPlate type
  • Pipe size
  • Liquid | Gas | Water1/4 | 5/8 | R1 inch
  • Power Supply Wire Indoor3×4.0 / 2×20 (bipolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire Outdoor3×4.0 / 2×20 (bipolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire3×1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor56/44/39 dB(A)
  • Indoor38/22 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor1.008x712x426 mm
  • Indoor600×1.943×600 mm
  • Net weight Outdoor/Indoor58/157 kg
  • Domestic Hot Water Tank
  • Volume240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure10 bar
  • MaterialStainless Steel
  • Outdoor air temperature range
  • Cooling-5~43 ⁰C
  • Heating-25~35 ⁰C
  • DHW-25~43 ⁰C
  • Water outlet temperature range
  • Cooling5~25 ⁰C
  • Heating25~65 ⁰C
  • DHW (tank)30~60 ⁰C
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity6.2 kW
  • Rated input1.24 kW
  • COP5.0
  • Water temperature 55°C
  • Capacity6.0 kW
  • Rated input2.03 kW
  • COP2.95
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity6.55 kW
  • Rated input1.34 kW
  • EER4.9
  • Water temperature 7°C
  • Capacity7.0 kW
  • Rated input2.33 kW
  • EER3.00
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%)195
  • classA+++
  • Water outlet at 55⁰C
  • ηs (%)137.9
  • classA++
  • SCOP (Average)
  • Water outlet at 35⁰C4.95
  • Water outlet at 55⁰C3.52
  • SEER
  • Water outlet at 7⁰C5.31
  • Water outlet at 18⁰C8.25
  • Power supply220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater3/1 kW/Ph
  • MOP/MCA18/14 A
  • Compressor
  • TipoTwin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.50 kg
  • Water side heat exchangerPlate type
  • Pipe size
  • Liquid | Gas | Water1/4 | 5/8 | R1 inch
  • Power Supply Wire Indoor3×4.0 / 2×20 (bipolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire Outdoor3×4.0 / 2×20 (bipolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire3×1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor58/45/40 dB(A)
  • Indoor38/24 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor1.008x712x426 mm
  • Indoor600×1.683×600 mm
  • Net weight Outdoor/Indoor58/140 kg
  • Domestic Hot Water Tank
  • Volume190 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure10 bar
  • MaterialStainless Steel
  • Outdoor air temperature range
  • Cooling-5~43 ⁰C
  • Heating-25~35 ⁰C
  • DHW-25~43 ⁰C
  • Water outlet temperature range
  • Cooling5~25 ⁰C
  • Heating25~65 ⁰C
  • DHW (tank)30~60 ⁰C
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity6.2 kW
  • Rated input1.24 kW
  • COP5.0
  • Water temperature 55°C
  • Capacity6.0 kW
  • Rated input2.03 kW
  • COP2.95
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity6.55 kW
  • Rated input1.34 kW
  • EER4.9
  • Water temperature 7°C
  • Capacity7.0 kW
  • Rated input2.33 kW
  • EER3.00
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%)195
  • classA+++
  • Water outlet at 55⁰C
  • ηs (%)137.9
  • classA++
  • SCOP (Average)
  • Water outlet at 35⁰C4.95
  • Water outlet at 55⁰C3.52
  • SEER
  • Water outlet at 7⁰C5.31
  • Water outlet at 18⁰C8.25
  • Power supply220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater3/1 kW/Ph
  • MOP/MCA18/14 A
  • Compressor
  • TipoTwin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.50 kg
  • Water side heat exchangerPlate type
  • Pipe size
  • Liquid | Gas | Water1/4 | 5/8 | R1 inch
  • Power Supply Wire Indoor3×4.0 / 2×20 (bipolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire Outdoor3×4.0 / 2×20 (bipolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire3×1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor58/45/40 dB(A)
  • Indoor38/24 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor1.008x712x426 mm
  • Indoor600×1.943×600 mm
  • Net weight Outdoor/Indoor58/157 kg
  • Domestic Hot Water Tank
  • Volume240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure10 bar
  • MaterialStainless Steel
  • Outdoor air temperature range
  • Cooling-5~43 ⁰C
  • Heating-25~35 ⁰C
  • DHW-25~43 ⁰C
  • Water outlet temperature range
  • Cooling5~25 ⁰C
  • Heating25~65 ⁰C
  • DHW (tank)30~60 ⁰C
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity8.3 kW
  • Rated input1.6 kW
  • COP5.2
  • Water temperature 55°C
  • Capacity7.5 kW
  • Rated input2.36 kW
  • COP3.18
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity8.4 kW
  • Rated input1.66 kW
  • EER5.05
  • Water temperature 7°C
  • Capacity7.4 kW
  • Rated input2.19 kW
  • EER3.38
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%)205.6
  • classA+++
  • Water outlet at 55⁰C
  • ηs (%)131.5
  • classA++
  • SCOP (Average)
  • Water outlet at 35⁰C5.22
  • Water outlet at 55⁰C3.36
  • SEER
  • Water outlet at 7⁰C5.83
  • Water outlet at 18⁰C8.95
  • Power supply220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater3/1 kW/Ph
  • MOP/MCA19/16 A
  • Compressor
  • TipoTwin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.65 kg
  • Water side heat exchangerPlate type
  • Pipe size
  • Liquid | Gas | Water3/8 | 5/8 | R1 inch
  • Power Supply Wire Indoor3×4.0 / 2×20 (bipolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire Outdoor3×4.0 / 2×20 (bipolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire3×1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor59/46/41 dB(A)
  • Indoor40/22 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor1.118x865x523 mm
  • Indoor600×1.683×600 mm
  • Net weight Outdoor/Indoor75/140 kg
  • Domestic Hot Water Tank
  • Volume190 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure10 bar
  • MaterialStainless Steel
  • Outdoor air temperature range
  • Cooling-5~43 ⁰C
  • Heating-25~35 ⁰C
  • DHW-25~43 ⁰C
  • Water outlet temperature range
  • Cooling5~25 ⁰C
  • Heating25~65 ⁰C
  • DHW (tank)30~60 ⁰C
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity8.3 kW
  • Rated input1.6 kW
  • COP5.2
  • Water temperature 55°C
  • Capacity7.5 kW
  • Rated input2.36 kW
  • COP3.18
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity8.4 kW
  • Rated input1.66 kW
  • EER5.05
  • Water temperature 7°C
  • Capacity7.4 kW
  • Rated input2.19 kW
  • EER3.38
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%)205.6
  • classA+++
  • Water outlet at 55⁰C
  • ηs (%)131.5
  • classA++
  • SCOP (Average)
  • Water outlet at 35⁰C5.22
  • Water outlet at 55⁰C3.36
  • SEER
  • Water outlet at 7⁰C5.83
  • Water outlet at 18⁰C8.95
  • Power supply220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater3/1 kW/Ph
  • MOP/MCA19/16 A
  • Compressor
  • TipoTwin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.65 kg
  • Water side heat exchangerPlate type
  • Pipe size
  • Liquid | Gas | Water3/8 | 5/8 | R1 inch
  • Power Supply Wire Indoor3×4.0 / 2×20 (bipolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire Outdoor3×4.0 / 2×20 (bipolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire3×1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor59/46/41 dB(A)
  • Indoor40/22 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor1.118x865x523 mm
  • Indoor600×1.943×600 mm
  • Net weight Outdoor/Indoor75/157 kg
  • Domestic Hot Water Tank
  • Volume240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure10 bar
  • MaterialStainless Steel
  • Outdoor air temperature range
  • Cooling-5~43 ⁰C
  • Heating-25~35 ⁰C
  • DHW-25~43 ⁰C
  • Water outlet temperature range
  • Cooling5~25 ⁰C
  • Heating25~65 ⁰C
  • DHW (tank)30~60 ⁰C
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity10.0 kW
  • Rated input2.0 kW
  • COP5.0
  • Water temperature 55°C
  • Capacity9.5 kW
  • Rated input3.06 kW
  • COP3.1
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity10.0 kW
  • Rated input2.08 kW
  • EER4.8
  • Water temperature 7°C
  • Capacity8.2 kW
  • Rated input2.48 kW
  • EER3.3
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%)204.8
  • classA+++
  • Water outlet at 55⁰C
  • ηs (%)136.6
  • classA++
  • SCOP (Average)
  • Water outlet at 35⁰C5.2
  • Water outlet at 55⁰C3.49
  • SEER
  • Water outlet at 7⁰C5.96
  • Water outlet at 18⁰C8.8
  • Power supply220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater3/1 kW/Ph
  • MOP/MCA19/17 A
  • Compressor
  • TipoTwin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.65 kg
  • Water side heat exchangerPlate type
  • Pipe size
  • Liquid | Gas | Water3/8 | 5/8 | R1 inch
  • Power Supply Wire Indoor3×4.0 / 2×20 (bipolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire Outdoor3×4.0 / 2×20 (bipolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire3×1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor60/49/41 dB(A)
  • Indoor40/22 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor1.118x865x523 mm
  • Indoor600×1.683×600 mm
  • Net weight Outdoor/Indoor75/140 kg
  • Domestic Hot Water Tank
  • Volume190 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure10 bar
  • MaterialStainless Steel
  • Outdoor air temperature range
  • Cooling-5~43 ⁰C
  • Heating-25~35 ⁰C
  • DHW-25~43 ⁰C
  • Water outlet temperature range
  • Cooling5~25 ⁰C
  • Heating25~65 ⁰C
  • DHW (tank)30~60 ⁰C
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity10.0 kW
  • Rated input2.0 kW
  • COP5.0
  • Water temperature 55°C
  • Capacity9.5 kW
  • Rated input3.06 kW
  • COP3.1
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity10.0 kW
  • Rated input2.08 kW
  • EER4.8
  • Water temperature 7°C
  • Capacity8.2 kW
  • Rated input2.48 kW
  • EER3.3
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%)204.8
  • classA+++
  • Water outlet at 55⁰C
  • ηs (%)136.6
  • classA++
  • SCOP (Average)
  • Water outlet at 35⁰C5.2
  • Water outlet at 55⁰C3.49
  • SEER
  • Water outlet at 7⁰C5.96
  • Water outlet at 18⁰C8.8
  • Power supply220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater3/1 kW/Ph
  • MOP/MCA19/17 A
  • Compressor
  • TipoTwin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.65 kg
  • Water side heat exchangerPlate type
  • Pipe size
  • Liquid | Gas | Water3/8 | 5/8 | R1 inch
  • Power Supply Wire Indoor3×4.0 / 2×20 (bipolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire Outdoor3×4.0 / 2×20 (bipolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire3×1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor60/49/41 dB(A)
  • Indoor40/22 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor1.118x865x523 mm
  • Indoor600×1.943×600 mm
  • Net weight Outdoor/Indoor75/157 kg
  • Domestic Hot Water Tank
  • Volume240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure10 bar
  • MaterialStainless Steel
  • Outdoor air temperature range
  • Cooling-5~43 ⁰C
  • Heating-25~35 ⁰C
  • DHW-25~43 ⁰C
  • Water outlet temperature range
  • Cooling5~25 ⁰C
  • Heating25~65 ⁰C
  • DHW (tank)30~60 ⁰C
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity12.1 kW
  • Rated input2.44 kW
  • COP4.95
  • Water temperature 55°C
  • Capacity11.9 kW
  • Rated input3.87 kW
  • COP3.05
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity12.0 kW
  • Rated input3.0 kW
  • EER4.0
  • Water temperature 7°C
  • Capacity11.6 kW
  • Rated input4.22 kW
  • EER2.75
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%)189.4
  • classA+++
  • Water outlet at 55⁰C
  • ηs (%)135.1
  • classA++
  • SCOP (Average)
  • Water outlet at 35⁰C4.81
  • Water outlet at 55⁰C3.45
  • SEER
  • Water outlet at 7⁰C4.93
  • Water outlet at 18⁰C7.14
  • Power supply220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater3/1 kW/Ph
  • MOP/MCA30/25 A
  • Compressor
  • TipoTwin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.84 kg
  • Water side heat exchangerPlate type
  • Pipe size
  • Liquid | Gas | Water3/8 | 5/8 | R1 inch
  • Power Supply Wire Indoor3×4.0 / 2×20 (bipolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire Outdoor3×6.0 / 2×25 (bipolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire3×1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor64/50/43 dB(A)
  • Indoor42/24 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor1.118x865x523 mm
  • Indoor600×1.943×600 mm
  • Net weight Outdoor/Indoor97/159 kg
  • Domestic Hot Water Tank
  • Volume240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure10 bar
  • MaterialStainless Steel
  • Outdoor air temperature range
  • Cooling-5~43 ⁰C
  • Heating-25~35 ⁰C
  • DHW-25~43 ⁰C
  • Water outlet temperature range
  • Cooling5~25 ⁰C
  • Heating25~65 ⁰C
  • DHW (tank)30~60 ⁰C
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity14.5 kW
  • Rated input3.09 kW
  • COP4.70
  • Water temperature 55°C
  • Capacity13.8 kW
  • Rated input4.60 kW
  • COP2.95
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity13.5 kW
  • Rated input3.74 kW
  • EER3.61
  • Water temperature 7°C
  • Capacity12.7 kW
  • Rated input4.98 kW
  • EER2.55
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%)185.7
  • classA+++
  • Water outlet at 55⁰C
  • ηs (%)135.6
  • classA++
  • SCOP (Average)
  • Water outlet at 35⁰C4.81
  • Water outlet at 55⁰C3.45
  • SEER
  • Water outlet at 7⁰C4.81
  • Water outlet at 18⁰C6.86
  • Power supply220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater3/1 kW/Ph
  • MOP/MCA30/26 A
  • Compressor
  • TipoTwin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.84 kg
  • Water side heat exchangerPlate type
  • Pipe size
  • Liquid | Gas | Water3/8 | 5/8 | R1 inch
  • Power Supply Wire Indoor3×4.0 / 2×20 (bipolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire Outdoor3×10.0 / 2×32 (bipolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire3×1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor65/51/43 dB(A)
  • Indoor44/25 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor1.118x865x523 mm
  • Indoor600×1.943×600 mm
  • Net weight Outdoor/Indoor97/159 kg
  • Domestic Hot Water Tank
  • Volume240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure10 bar
  • MaterialStainless Steel
  • Outdoor air temperature range
  • Cooling-5~43 ⁰C
  • Heating-25~35 ⁰C
  • DHW-25~43 ⁰C
  • Water outlet temperature range
  • Cooling5~25 ⁰C
  • Heating25~65 ⁰C
  • DHW (tank)30~60 ⁰C
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity16.0 kW
  • Rated input3.56 kW
  • COP4.50
  • Water temperature 55°C
  • Capacity16.0 kW
  • Rated input5.52 kW
  • COP2.85
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity14.2 kW
  • Rated input3.94 kW
  • EER3.61
  • Water temperature 7°C
  • Capacity14.0 kW
  • Rated input5.71 kW
  • EER2.45
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%)181.7
  • classA+++
  • Water outlet at 55⁰C
  • ηs (%)133.3
  • classA++
  • SCOP (Average)
  • Water outlet at 35⁰C4.72
  • Water outlet at 55⁰C3.47
  • SEER
  • Water outlet at 7⁰C4.6
  • Water outlet at 18⁰C6.67
  • Power supply220-240/50/1 V/Hz/Ph
  • Auxiliary Electric Heater3/1 kW/Ph
  • MOP/MCA30/27 A
  • Compressor
  • TipoTwin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.84 kg
  • Water side heat exchangerPlate type
  • Pipe size
  • Liquid | Gas | Water3/8 | 5/8 | R1 inch
  • Power Supply Wire Indoor3×4.0 / 2×20 (bipolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire Outdoor3×10.0 / 2×32 (bipolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire3×1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor68/54/43 dB(A)
  • Indoor44/24 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor1.118x865x523 mm
  • Indoor600×1.943×600 mm
  • Net weight Outdoor/Indoor97/159 kg
  • Domestic Hot Water Tank
  • Volume240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure10 bar
  • MaterialStainless Steel
  • Outdoor air temperature range
  • Cooling-5~43 ⁰C
  • Heating-25~35 ⁰C
  • DHW-25~43 ⁰C
  • Water outlet temperature range
  • Cooling5~25 ⁰C
  • Heating25~65 ⁰C
  • DHW (tank)30~60 ⁰C
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity12.1 kW
  • Rated input2.44 kW
  • COP4.95
  • Water temperature 55°C
  • Capacity11.9 kW
  • Rated input3.87 kW
  • COP3.05
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity12.0 kW
  • Rated input3.00 kW
  • EER4.0
  • Water temperature 7°C
  • Capacity11.6 kW
  • Rated input4.22 kW
  • EER2.75
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%)189.3
  • classA+++
  • Water outlet at 55⁰C
  • ηs (%)135.1
  • classA++
  • SCOP (Average)
  • Water outlet at 35⁰C4.72
  • Water outlet at 55⁰C3.47
  • SEER
  • Water outlet at 7⁰C4.83
  • Water outlet at 18⁰C7.0
  • Power supply380-415/50/3 V/Hz/Ph
  • Auxiliary Electric Heater9/3 kW/Ph
  • MOP/MCA14/10 A
  • Compressor
  • TipoTwin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.84 kg
  • Water side heat exchangerPlate type
  • Pipe size
  • Liquid | Gas | Water3/8 | 5/8 | R1 inch
  • Power Supply Wire Indoor5×2.5 / 4×16 (quadpolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire Outdoor5×2.5 / 4×16 (quadpolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire3×1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor64/50/43 dB(A)
  • Indoor42/24 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor1.118x865x523 mm
  • Indoor600×1.943×600 mm
  • Net weight Outdoor/Indoor112/159 kg
  • Domestic Hot Water Tank
  • Volume240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure10 bar
  • MaterialStainless Steel
  • Outdoor air temperature range
  • Cooling-5~43 ⁰C
  • Heating-25~35 ⁰C
  • DHW-25~43 ⁰C
  • Water outlet temperature range
  • Cooling5~25 ⁰C
  • Heating25~65 ⁰C
  • DHW (tank)30~60 ⁰C
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity14.5 kW
  • Rated input3.09 kW
  • COP4.7
  • Water temperature 55°C
  • Capacity13.8 kW
  • Rated input4.6 kW
  • COP2.95
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity13.5 kW
  • Rated input3.74 kW
  • EER3.61
  • Water temperature 7°C
  • Capacity12.7 kW
  • Rated input4.98 kW
  • EER2.55
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%)185.6
  • classA+++
  • Water outlet at 55⁰C
  • ηs (%)135.6
  • classA++
  • SCOP (Average)
  • Water outlet at 35⁰C4.62
  • Water outlet at 55⁰C3.41
  • SEER
  • Water outlet at 7⁰C4.79
  • Water outlet at 18⁰C6.81
  • Power supply380-415/50/3 V/Hz/Ph
  • Auxiliary Electric Heater9/3 kW/Ph
  • MOP/MCA14/11 A
  • Compressor
  • TipoTwin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.84 kg
  • Water side heat exchangerPlate type
  • Pipe size
  • Liquid | Gas | Water3/8 | 5/8 | R1 inch
  • Power Supply Wire Indoor5×2.5 / 4×16 (quadpolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire Outdoor5×2.5 / 4×16 (quadpolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire3×1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor65/51/43 dB(A)
  • Indoor44/25 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor1.118x865x523 mm
  • Indoor600×1.943×600 mm
  • Net weight Outdoor/Indoor112/159 kg
  • Domestic Hot Water Tank
  • Volume240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure10 bar
  • MaterialStainless Steel
  • Outdoor air temperature range
  • Cooling-5~43 ⁰C
  • Heating-25~35 ⁰C
  • DHW-25~43 ⁰C
  • Water outlet temperature range
  • Cooling5~25 ⁰C
  • Heating25~65 ⁰C
  • DHW (tank)30~60 ⁰C
  • Heating
    at Αmbient Temperature 7°C
  • Water temperature 35°C
  • Capacity16.0 kW
  • Rated input3.56 kW
  • COP4.5
  • Water temperature 55°C
  • Capacity16.0 kW
  • Rated input5.52 kW
  • COP2.85
  • Cooling
    at Ambient Temperature 35°C
  • Water temperature 18°C
  • Capacity14.2 kW
  • Rated input3.94 kW
  • EER3.61
  • Water temperature 7°C
  • Capacity14.0 kW
  • Rated input5.71 kW
  • EER2.45
  • Seasonal space heating
    energy efficiency class
    (Average)
  • Water outlet at 35⁰C
  • ηs (%)181.6
  • classA+++
  • Water outlet at 55⁰C
  • ηs (%)133.2
  • classA++
  • SCOP (Average)
  • Water outlet at 35⁰C4.62
  • Water outlet at 55⁰C3.41
  • SEER
  • Water outlet at 7⁰C4.58
  • Water outlet at 18⁰C6.63
  • Power supply380-415/50/3 V/Hz/Ph
  • Auxiliary Electric Heater9/3 kW/Ph
  • MOP/MCA14/12 A
  • Compressor
  • TipoTwin rotary Mitsubishi
  • Refrigerant
  • Type / Charged volume
    (up to 15m)
    R32/1.84 kg
  • Water side heat exchangerPlate type
  • Pipe size
  • Liquid | Gas | Water3/8 | 5/8 | R1 inch
  • Power Supply Wire Indoor5×2.5 / 4×16 (quadpolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire Outdoor5×2.5 / 4×16 (quadpolar fuse kinetic) No x mm² / No x Α
  • Power Supply Wire3×1.0 shielded No x mm² / No x Α
  • Sound (power/pressure/ pressure silent 2)
  • Outdoor68/55/43 dB(A)
  • Indoor44/24 dB(A)
  • Unit dimension (WxHxD)
  • Outdoor1.118x865x523 mm
  • Indoor600×1.943×600 mm
  • Net weight Outdoor/Indoor112/159 kg
  • Domestic Hot Water Tank
  • Volume240 L
  • Max Water Temperature
    (during Disinfection)
    70 ⁰C
  • Max Water Pressure10 bar
  • MaterialStainless Steel
  • Outdoor air temperature range
  • Cooling-5~43 ⁰C
  • Heating-25~35 ⁰C
  • DHW-25~43 ⁰C
  • Water outlet temperature range
  • Cooling5~25 ⁰C
  • Heating25~65 ⁰C
  • DHW (tank)30~60 ⁰C

More

Zone Control

With the use of external thermostats you can set up to 8 different zones*, thus covering all the different thermal needs of the space and achieve maximum energy savings and comfort. The water circuit can be separated into 2 different zones. *For more than 2 zones, AT-TCK-6 installation is required

Holiday Mode

Reduce energy consumption while saving money even when away from home with the Holiday Away mode. You can additionally program the heat pump with different operation settings through the Holiday Home mode, to activate quick and easy when your home activity changes from your typical daily schedule.

Modbus RTU

Connect up to 16 heat pumps with your building management system through Modbus RTU protocol to fully incorporate to your smart house/building and achieve complete control of the environment of your space.

Auto Restart

In case of a power failure, the heat pump will automatically restart according to the previous settings.