MFVI32-09WFI / MFVO32-09
Cooling Capacity | 8.870 (2.730-10.920) Btu / h | |
Cooling Capacity | 2.6 (0.8-3.2) kWatt | |
Heating Capacity | 10.920 (2.730-14.330) Btu / h | |
Heating Capacity | 3.2 (0.8-4.2) kWatt | |
Seasonal Efficiency(In accordance to ΕΝ14.825) | Cooling | |
Pdesign | 2.6 kW | |
Energy Class | A++ | |
SEER | 8.5 | |
Energy Consumption | 107 kWh / year | |
Heating | Middle Zone | |
Pdesign | 2.4 kW) | |
Energy Class | Α+ | |
SCOP | 4.6 | |
Energy Consumption | 731 kWh / year | |
Heating | Warm Zone | |
Pdesign | 2.6 kW | |
Energy Class | A+++ | |
SCOP | 5.5 | |
Energy Consumption | 662 kWh / year | |
Voltage / Frequency / Phase | 220 - 240 / 50 / 1 V / Hz / Ph | |
Current Input Cooling | 2.9 (0.9-6.7) Α | |
Current Input Heating | 3.6 (1.3-7.2) Α | |
Power Input Cooling | 0.65 (0.2-1.5) kW | |
Power Input Heating | 0.8 (0.3-1.6) kW | |
Air Flow Volume(High/Medium/Low) | 650/600/500/350/250 m³ / h | |
Noise Level Indoor Unit (Silent / Low / Med / Hi) | 16/25/32/38 db(A) | |
Noise Level - Outdoor unit | 47 db(A) | |
Sound Power Level Outdoor Unit | 53 db(A) | |
Sound Power Level Outdoor Unit | 59 db(A) | Dehumidifying Volume | 1.2 L/h |
Dehumidifying Volume | 28.8 L/day | |
Compressor Type | Panasonic | |
Liquid Line / Gas Line | 1 / 4” | 3 / 8” | |
Power Supply Wire Outdoor | 3 x 1.5 / 10 No x mm² / A | |
Signal Wires | 4 × 1.5 No x mm² | |
Dimensions Indoor Unit(WxDxH) | 856/197/300 mm | |
DimensionsOutdoor Unit(WxDxH) | 800/275/553 mm | |
Net Weight Indoor / Outdoor | 9.5/29.0 kg | |
Refrigerant / Charge | R32 / 650 g | |
Operation Temperature Range Outdoor Unit Heating | -20~43 °C | |
Operation Temperature Range Outdoor Unit Heating | -20~24 °C |
MFVI32-12WFI / MFVO32-12
Cooling Capacity | 11.940 (3.410-13.650) Btu / h | |
Cooling Capacity | 3.5 (1.0-4.0) kWatt | |
Heating Capacity | 14.330 (3.410-17.740) Btu / h | |
Heating Capacity | 4.2 (1.0-5.2) kWatt | |
Seasonal Efficiency(In accordance to ΕΝ14.825) | Cooling | |
Pdesign | 3.5 kW | |
Energy Class | A++ | |
SEER | 8.5 | |
Energy Consumption | 144 kWh / year | |
Heating | Middle Zone | |
Pdesign | 2.8 kW) | |
Energy Class | Α+ | |
SCOP | 4.6 | |
Energy Consumption | 854 kWh / year | |
Heating | Warm Zone | |
Pdesign | 3.0 kW | |
Energy Class | A+++ | |
SCOP | 5.5 | |
Energy Consumption | 756 kWh / year | |
Voltage / Frequency / Phase | 220 - 240 / 50 / 1 V / Hz / Ph | |
Current Input Cooling | 3.9 (1.4-6.7) Α | |
Current Input Heating | 5.0 (2.3-7.2) Α | |
Power Input Cooling | 0.88 (0.3-1.5) kW | |
Power Input Heating | 1.1 (0.5-1.6) kW | |
Air Flow Volume(High/Medium/Low) | 700/650/550/400/300 m³ / h | |
Noise Level Indoor Unit (Silent / Low / Med / Hi) | 17/26/33/39 db(A) | |
Noise Level - Outdoor unit | 48 db(A) | |
Sound Power Level Outdoor Unit | 55 db(A) | |
Sound Power Level Outdoor Unit | 61 db(A) | Dehumidifying Volume | 1.6 L/h |
Dehumidifying Volume | 38.4 L/day | |
Compressor Type | Hitachi | |
Liquid Line / Gas Line | 1 / 4” | 3 / 8” | |
Power Supply Wire Outdoor | 3 x 1.5 / 10 No x mm² / A | |
Signal Wires | 4 × 1.5 No x mm² | |
Dimensions Indoor Unit(WxDxH) | 856/197/300 mm | |
DimensionsOutdoor Unit(WxDxH) | 800/275/553 mm | |
Net Weight Indoor / Outdoor | 9.5/31.5 kg | |
Refrigerant / Charge | R32 / 940 g | |
Operation Temperature Range Outdoor Unit Heating | -20~43 °C | |
Operation Temperature Range Outdoor Unit Heating | -20~24 °C |
MFVI32-18WFI / MFVO32-18
Cooling Capacity | 17.740 (4.770-20.470) Btu / h | |
Cooling Capacity Range | 5.2 (1.4-6.0) kWatt | |
Heating Capacity | 20.470 (4.770-23.540) Btu / h | |
Heating Capacity | 6.0 (1.4-6.9) kWatt | |
Seasonal Efficiency(In accordance to ΕΝ14.825) | Cooling | |
Pdesign | 5.2 kW | |
Energy Class | A++ | |
SEER | 7.2 | |
Energy Consumption | 253 kWh / year | |
Heating | Middle Zone | |
Pdesign | 4.6 kW/b>) | |
Energy Class | Α+ | |
SCOP | 4.6 | |
Energy Consumption | 1.401 kWh / year | |
Heating | Warm Zone | |
Pdesign | 4.8 kW | |
Energy Class | A+++ | |
SCOP | 5.6 | |
Energy Consumption | 1.190 kWh / year | |
Voltage / Frequency / Phase | 220 - 240 / 50 / 1 V / Hz / Ph | |
Current Input Cooling | 6.2 (1.8-8.9) Α | |
Current Input Heating | 6.7 (2.3-10.9) Α | |
Power Input Cooling | 1.4 (0.5-2.0) kW | |
Power Input Heating | 1.5 (0.52-2.35) kW | |
Air Flow Volume(High/Medium/Low) | 1.050/900/750/650/550 m³ / h | |
Noise Level Indoor Unit (Silent / Low / Med / Hi) | 28/37/41/45 db(A) | |
Noise Level - Outdoor unit | 51 db(A) | |
Sound Power Level Outdoor Unit | 57 db(A) | |
Sound Power Level Outdoor Unit | 63 db(A) | Dehumidifying Volume | 2.0 L/h |
Dehumidifying Volume | 48.0 L/day | |
Compressor Type | Mitsubishi | |
Liquid Line / Gas Line | 1 / 4” | 1 / 2” | |
Power Supply Wire Outdoor | 3 x 2.5 / 16 No x mm² / A | |
Signal Wires | 4 × 1.5 No x mm² | |
Dimensions Indoor Unit(WxDxH) | 999/225/323 mm | |
DimensionsOutdoor Unit(WxDxH) | 820/338/614 mm | |
Net Weight Indoor / Outdoor | 12.0/37.8 kg | |
Refrigerant / Charge | R32 / 950 g | |
Operation Temperature Range Outdoor Unit Heating | -20~43 °C | |
Operation Temperature Range Outdoor Unit Heating | -20~24 °C |
MFVI32-24WFI / MFVO32-24
Cooling Capacity | 23.890 (7.510-25.600) Btu / h | |
Cooling Capacity Range | 7.0 (2.2-7.5) kWatt | |
Heating Capacity | 27.300 (8.190-29.000) Btu / h | |
Heating Capacity | 8.0 (2.4-8.5) kWatt | |
Seasonal Efficiency(In accordance to ΕΝ14.825) | Cooling | |
Pdesign | 7.0 kW | |
Energy Class | A++ | |
SEER | 7.0 | |
Energy Consumption | 345 kWh / year | |
Heating | Middle Zone | |
Pdesign | 5.6 kW | |
Energy Class | Α+ | |
SCOP | 4.0 | |
Energy Consumption | 1.959 kWh / year | |
Heating | Warm Zone | |
Pdesign | 5.2 kW | |
Energy Class | A+++ | |
SCOP | 5.4 | |
Energy Consumption | 1.357 kWh / year | |
Voltage / Frequency / Phase | 220 - 240 / 50 / 1 V / Hz / Ph | |
Current Input Cooling | 9.6 (3.2-11.2) Α | |
Current Input Heating | 9.6 (3.2-13.0) Α | |
Power Input Cooling | 2.17 (0.7-2.5) kW | |
Power Input Heating | 2.16 (0.7-2.9) kW | |
Air Flow Volume(High/Medium/Low) | 1.250/1.100/950/850/700 m³ / h | |
Noise Level Indoor Unit (Silent / Low / Med / Hi) | 33/37/43/47 db(A) | |
Noise Level - Outdoor unit | 60 db(A) | |
Sound Power Level Outdoor Unit | 60 db(A) | |
Sound Power Level Outdoor Unit | 70 db(A) | Dehumidifying Volume | 2.8 L/h |
Dehumidifying Volume | 67.2 L/day | |
Compressor Type | Mitsubishi | |
Liquid Line / Gas Line | 3 / 8” | 5 / 8” | |
Power Supply Wire Outdoor | 3 x 2.5 / 16 No x mm² / A | |
Signal Wires | 4 × 1.5 No x mm² | |
Dimensions Indoor Unit(WxDxH) | 1.115/235/343 mm | |
DimensionsOutdoor Unit(WxDxH) | 890/353/697 mm | |
Net Weight Indoor / Outdoor | 15.2/45.0 kg | |
Refrigerant / Charge | R32 / 1.300 g | |
Operation Temperature Range Outdoor Unit Heating | -20~43 °C | |
Operation Temperature Range Outdoor Unit Heating | -20~24 °C |
Ideal temperature of high air quality in your place!
Comfort air conditioner series creates the ideal atmosphere conditions in your place, ensuring ideal temperature and excellent air quality while offering the ultimate protection to you and your beloved. With the Ultraviolet Type C Technology & Ionizer function, malicious floating particles are removed to obtain a healthy atmosphere in your place. 56°C Sterilization function ensures a high air quality by cleaning the interior of the unit. The Motion Sensor allows you to adjust the operation of the unit so that the airflow is directed towards or against the point movement is detected, ensuring energy and money savings. Inventor Control app offers the ultimate control of the unit with multiple options and functions from anywhere you are through your smartphone or tablet.
5 Year Warranty for all Inventor Air Conditioners
All Inventor Air Conditioners are accompanied with a 5-year warranty card. Their high production quality ensures their impeccable performance and long term operation, even in the most demanding conditions.
Ultraviolet Type C Technology & Ionizer
Provide a clean atmosphere in your space free of germs and bacteria thanks to Ultraviolet technology type C and the Ionizer. Ultraviolet Type C technology takes care of the hygiene of your space, effectively neutralizing microorganisms, thanks to the lamp UV that produces 265-275nm wave C type UV radiation. Removes effectively the SARS-CoV-2 virus (Covid-19) 99.998%, the Influenza A H3N2 influenza virus 91.47% and the bacterium Staphylococcus albus 92.78%. The Ionizer contributes in a natural & effective way to the removal of harmful suspended particles, such as germs, bacteria, pollen viruses, tobacco dust, odors, etc., offering a constant feeling of freshness.
- According to measurements made in Texcell laboratories, it inactivates 99.998% of the SARS-CoV-2 virus (Covid-19) of the coronavirus family after 1 hour of operation in 45L space.
Motion Sensor
Create ideal conditions in your space, saving energy, with the innovative technology of the Motion Sensor. Adjust the airflow direction of your air conditioner where you are or vice versa and enjoy excellent comfort conditions. In addition, save money, thanks to the Motion Sensor’s ability to reduce or enhance performance whenever it detects your presence or absence from the room.
Ultra Silence Mode 16dB(A)
Activate the silent operation of your air conditioner and enjoy the feeling of absolute silence. Thanks to the special design and the advanced technology of the air conditioner, you enjoy a low noise level, from 16dB(A).
56°C Sterilization
Take care of your health and the best air quality with the 56°C Sterilization function. The high temperature of 56°C that develops inside the unit sterilizes the device and neutralizes viruses and bacteria, such as the H1N1 virus and the bacterium Escherichia coli (99.9% sterilization rate), while removing the accumulated dust from inside.
*The 56°C Sterilization Mode can only be activated by the Inventor Control application.
Reviews