ATS08S/HU100S3
Heating (Average) at Αmbient Temperature 7°C
Water temperature 35°C
Capacity | 8.3 kW |
---|---|
Rated input | 1.6 kW |
COP | 5.2 |
Water temperature 55°C | |
Capacity | 7.5 kW |
Rated input | 2.36 kW |
COP | 3.18 |
Cooling at Ambient Temperature 35°C | |
Water temperature 18°C | |
Capacity | 8.4 kW |
Rated input | 1.66 kW |
EER | 5.05 |
Water temperature 7°C | |
Capacity | 7.4 kW |
Rated input | 2.19 kW |
EER | 3.38 |
Seasonal space heating energy efficiency class (Average) | |
Water outlet at 35⁰C | |
ηs (%) | 205 |
Energy Class | A+++ |
Water outlet at 55⁰C | |
ηs (%) | 131 |
Energy Class | A++ |
SCOP (Average) | |
Water outlet at 35⁰C | 5.21 |
Water outlet at 55⁰C | 3.36 |
SEER | |
Water outlet at 7⁰C | 5.83 |
Water outlet at 18⁰C | 8.95 |
Power supply | 220-240/50/1 V/Ph/Hz |
Auxiliary Electric Heater | 3/1 kW/Ph |
MOP/MCA | 19/16 A |
Compressor | |
Type | Twin rotary Mitsubishi |
Refrigerant | |
Type / Charged volume (up to 15m) | R32/1.65 kg |
Water side heat exchanger | Plate type |
Pipe size | |
Liquid | Gas | Water (inner dimension) | 3/8 | 5/8 | R1 inch |
Power Supply Wire Indoor | 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α |
Power Supply Wire Outdoor | 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α |
Signal Wires | 3x1.0 shielded No x mm² / No x Α |
Sound (Power/Pressure/ Pressure silent 2) | |
Outdoor | 59/46/41 dB(A) |
Indoor | 42/30 dB(A) |
Unit dimension (WxHxD) | |
Outdoor | 1.118x865x523 mm |
Indoor | 420x790x270 mm |
Net weight ODU/IDU | 78.5/43 kg |
Outdoor air temperature range | |
Cooling | -5~43 ⁰C |
Heating | -25~35 ⁰C |
DHW | -25~43 ⁰C |
Water outlet temperature range | |
Cooling | 5~30 ⁰C |
Heating | 12~65 ⁰C |
DHW (tank) | 10~60 ⁰C |
ATS10S/HU100S3
Heating (Average) at Αmbient Temperature 7°C
Water temperature 35°C
Capacity | 10.0 kW |
---|---|
Rated input | 2.0 kW |
COP | 5.0 |
Water temperature 55°C | |
Capacity | 9.5 kW |
Rated input | 3.06 kW |
COP | 3.1 |
Cooling at Ambient Temperature 35°C | |
Water temperature 18°C | |
Capacity | 10.0 kW |
Rated input | 2.08 kW |
EER | 4.8 |
Water temperature 7°C | |
Capacity | 8.2 kW |
Rated input | 2.48 kW |
EER | 3.3 |
Seasonal space heating energy efficiency class (Average) | |
Water outlet at 35⁰C | |
ηs (%) | 204 |
Energy Class | A+++ |
Water outlet at 55⁰C | |
ηs (%) | 136 |
Energy Class | A++ |
SCOP (Average) | |
Water outlet at 35⁰C | 5.19 |
Water outlet at 55⁰C | 3.49 |
SEER | |
Water outlet at 7⁰C | 5.98 |
Water outlet at 18⁰C | 8.78 |
Power supply | 220-240/50/1 V/Ph/Hz |
Auxiliary Electric Heater | 3/1 kW/Ph |
MOP/MCA | 19/17 A |
Compressor | |
Type | Twin rotary Mitsubishi |
Refrigerant | |
Type / Charged volume (up to 15m) | R32/1.65 kg |
Water side heat exchanger | Plate type |
Pipe size | |
Liquid | Gas | Water (inner dimension) | 3/8 | 5/8 | R1 inch |
Power Supply Wire Indoor | 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α |
Power Supply Wire Outdoor | 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α |
Signal Wires | 3x1.0 shielded No x mm² / No x Α |
Sound (Power/Pressure/ Pressure silent 2) | |
Outdoor | 60/49/41 dB(A) |
Indoor | 42/30 dB(A) |
Unit dimension (WxHxD) | |
Outdoor | 1.118x865x523 mm |
Indoor | 420x790x270 mm |
Net weight ODU/IDU | 78.5/43 kg |
Outdoor air temperature range | |
Cooling | -5~43 ⁰C |
Heating | -25~35 ⁰C |
DHW | -25~43 ⁰C |
Water outlet temperature range | |
Cooling | 5~30 ⁰C |
Heating | 12~65 ⁰C |
DHW (tank) | 10~60 ⁰C |
ATS12S/HU160S3
Heating (Average) at Αmbient Temperature 7°C
Water temperature 35°C
Capacity | 12.1 kW |
---|---|
Rated input | 2.44 kW |
COP | 4.95 |
Water temperature 55°C | |
Capacity | 12.0 kW |
Rated input | 3.87 kW |
COP | 3.1 |
Cooling at Ambient Temperature 35°C | |
Water temperature 18°C | |
Capacity | 12.0 kW |
Rated input | 3.0 kW |
EER | 4.0 |
Water temperature 7°C | |
Capacity | 11.6 kW |
Rated input | 4.22 kW |
EER | 2.75 |
Seasonal space heating energy efficiency class (Average) | |
Water outlet at 35⁰C | |
ηs (%) | 189 |
Energy Class | A+++ |
Water outlet at 55⁰C | |
ηs (%) | 135 |
Energy Class | A++ |
SCOP (Average) | |
Water outlet at 35⁰C | 4.81 |
Water outlet at 55⁰C | 3.45 |
SEER | |
Water outlet at 7⁰C | 4.89 |
Water outlet at 18⁰C | 7.1 |
Power supply | 220-240/50/1 V/Ph/Hz |
Auxiliary Electric Heater | 3/1 kW/Ph |
MOP/MCA | 30/25 A |
Compressor | |
Type | Twin rotary Mitsubishi |
Refrigerant | |
Type / Charged volume (up to 15m) | R32/1.84 kg |
Water side heat exchanger | Plate type |
Pipe size | |
Liquid | Gas | Water (inner dimension) | 3/8 | 5/8 | R1 inch |
Power Supply Wire Indoor | 3x4.0 / 2x20 (bipolar fuse kinetic) No x mm² / No x Α |
Power Supply Wire Outdoor | 3x6.0 / 2x25 (bipolar fuse kinetic) No x mm² / No x Α |
Signal Wires | 3x1.0 shielded No x mm² / No x Α |
Sound (Power/Pressure/ Pressure silent 2) | |
Outdoor | 64/50/43 dB(A) |
Indoor | 43/32 dB(A) |
Unit dimension (WxHxD) | |
Outdoor | 1.118x865x523 mm |
Indoor | 420x790x270 mm |
Net weight ODU/IDU | 100/45 kg |
Outdoor air temperature range | |
Cooling | -5~43 ⁰C |
Heating | -25~35 ⁰C |
DHW | -25~43 ⁰C |
Water outlet temperature range | |
Cooling | 5~30 ⁰C |
Heating | 12~65 ⁰C |
DHW (tank) | 10~60 ⁰C |
ATS14T/HU160T9
Heating (Average) at Αmbient Temperature 7°C
Water temperature 35°C
Capacity | 14.5 kW |
---|---|
Rated input | 3.09 kW |
COP | 4.7 |
Water temperature 55°C | |
Capacity | 13.8 kW |
Rated input | 4.6 kW |
COP | 3.0 |
Cooling at Ambient Temperature 35°C | |
Water temperature 18°C | |
Capacity | 13.5 kW |
Rated input | 3.75 kW |
EER | 3.6 |
Water temperature 7°C | |
Capacity | 12.7 kW |
Rated input | 4.98 kW |
EER | 2.55 |
Seasonal space heating energy efficiency class (Average) | |
Water outlet at 35⁰C | |
ηs (%) | 185 |
Energy Class | A+++ |
Water outlet at 55⁰C | |
ηs (%) | 135 |
Energy Class | A++ |
SCOP (Average) | |
Water outlet at 35⁰C | 4.72 |
Water outlet at 55⁰C | 3.47 |
SEER | |
Water outlet at 7⁰C | 4.83 |
Water outlet at 18⁰C | 6.85 |
Power supply | 380-415/50/3 V/Ph/Hz |
Auxiliary Electric Heater | 9/3 kW/Ph |
MOP/MCA | 14/11 A |
Compressor | |
Type | Twin rotary Mitsubishi |
Refrigerant | |
Type / Charged volume (up to 15m) | R32/1.84 kg |
Water side heat exchanger | Plate type |
Pipe size | |
Liquid | Gas | Water (inner dimension) | 3/8 | 5/8 | R1 inch |
Power Supply Wire Indoor | 5x4.0 / 4x20 (bipolar fuse kinetic) No x mm² / No x Α |
Power Supply Wire Outdoor | 5x2.5 / 4x20 (quadpolar fuse kinetic) No x mm² / No x Α |
Signal Wires | 3x1.0 shielded No x mm² / No x Α |
Sound (Power/Pressure/ Pressure silent 2) | |
Outdoor | 65/51/43 dB(A) |
Indoor | 43/32 dB(A) |
Unit dimension (WxHxD) | |
Outdoor | 1.118x865x523 mm |
Indoor | 420x790x270 mm |
Net weight ODU/IDU | 116/45 kg |
Outdoor air temperature range | |
Cooling | -5~43 ⁰C |
Heating | -25~35 ⁰C |
DHW | -25~43 ⁰C |
Water outlet temperature range | |
Cooling | 5~30 ⁰C |
Heating | 12~65 ⁰C |
DHW (tank) | 10~60 ⁰C |
ATS16T/HU160T9
Heating (Average) at Αmbient Temperature 7°C
Water temperature 35°C
Capacity | 16.0 kW |
---|---|
Rated input | 3.56 kW |
COP | 4.5 |
Water temperature 55°C | |
Capacity | 16.0 kW |
Rated input | 5.52 kW |
COP | 2.9 |
Cooling at Ambient Temperature 35°C | |
Water temperature 18°C | |
Capacity | 14.9 kW |
Rated input | 4.38 kW |
EER | 3.4 |
Water temperature 7°C | |
Capacity | 14.0 kW |
Rated input | 5.71 kW |
EER | 2.45 |
Seasonal space heating energy efficiency class (Average) | |
Water outlet at 35⁰C | |
ηs (%) | 182 |
Energy Class | A+++ |
Water outlet at 55⁰C | |
ηs (%) | 133 |
Energy Class | A++ |
SCOP (Average) | |
Water outlet at 35⁰C | 4.62 |
Water outlet at 55⁰C | 3.41 |
SEER | |
Water outlet at 7⁰C | 4.67 |
Water outlet at 18⁰C | 6.71 |
Power supply | 380-415/50/3 V/Ph/Hz |
Auxiliary Electric Heater | 9/3 kW/Ph |
MOP/MCA | 14/12 A |
Compressor | |
Type | Twin rotary Mitsubishi |
Refrigerant | |
Type / Charged volume (up to 15m) | R32/1.84 kg |
Water side heat exchanger | Plate type |
Pipe size | |
Liquid | Gas | Water (inner dimension) | 3/8 | 5/8 | R1 inch |
Power Supply Wire Indoor | 5x4.0 / 4x20 (bipolar fuse kinetic) No x mm² / No x Α |
Power Supply Wire Outdoor | 5x2.5 / 4x20 (quadpolar fuse kinetic) No x mm² / No x Α |
Signal Wires | 3x1.0 shielded No x mm² / No x Α |
Sound (Power/Pressure/ Pressure silent 2) | |
Outdoor | 68/55/43 dB(A) |
Indoor | 43/32 dB(A) |
Unit dimension (WxHxD) | |
Outdoor | 1.118x865x523 mm |
Indoor | 420x790x270 mm |
Net weight ODU/IDU | 116/45 kg |
Outdoor air temperature range | |
Cooling | -5~43 ⁰C |
Heating | -25~35 ⁰C |
DHW | -25~43 ⁰C |
Water outlet temperature range | |
Cooling | 5~30 ⁰C |
Heating | 12~65 ⁰C |
DHW (tank) | 10~60 ⁰C |
3 Year Warranty for all Inventor Heat Pumps
All Inventor Heat Pumps are accompanied with a 3-year warranty card. Their high production quality ensures their impeccable performance and long term operation, even in the most demanding conditions.
Advanced technology for comfort and flexibility combined with maximum performance and energy saving!
Matrix air to water heat pumps, are the ideal solution for heating, cooling, and domestic hot water (DHW). Combining both comfort and energy efficiency, they are specifically designed to cover the needs of your household such as: floor heating and cooling, space heating with radiators, cooling and Heating with fan coils and domestic hot water. With high efficiency level thanks to the A+++ energy class, the plate heat exchanger, and the DC Inverter water pump, the heat pumps can offer ideal conditions even in the most extreme outdoor conditions. In addition to that, and thanks to the touch wired controller and its multiple functions, you can have absolute control over your appliance, while with the Wi-Fi Standard option, you can manage it from anywhere you are!
A+++ Energy Class
The technological superiority of Inventor heat pumps guarantees excellent performance with the lowest functional cost. Benefit from the highest energy class A+++ (heating – warm zone) and save energy while creating the desired conditions.
High efficiency even at low outdoor ambient temperatures
The heat pumps, thanks to their special design, with supply temperature up to 65°C for connection to heating radiators, offer cooling, heating as well as hot water production. At the same time, their smooth operation is ensured even at extreme outdoor temperatures that reach down to -25°C.
Ultimate Central Control
The heat pumps are equipped with a touch wired controller for an even easier usage of your appliance, offering access to an important number of functions.
• Set the heat pump to operate according to your weekly schedule and enjoy ideal conditions in your space and availability of DHW when in need, saving energy and money on a daily basis, thanks to the Weekly Timer.
• Activate the Eco function and reduce the power consumption saving energy and money.
• Reduce energy consumption while saving money even when away from home with the Holiday Away mode. You can additionally program the heat pump with different operation settings through the Holiday Home mode, to activate quick and easy when your home activity changes from your typical daily schedule.
• Achieve ideal conditions in your space by using the wired controller as an external thermostat. The built-in temperature sensor will provide accurate room temperature information to the heat pump, for increased comfort.
Wi-Fi Standard
Through the smart Wi-Fi management, you get to create the environment you desire, from anywhere. Free download the Comfort Home app from Google Play or App Store and save energy operating your appliance through your smartphone or tablet.
Plate Heat Exchanger
Equipped with a resilient plate heat exchanger of high thermal transfer coefficient, Inventor heat pumps provide energy savings and ensure long and stellar operation.
DC Inverter Water Pump
Equipped with a reliable water pump from Wilo or Grundfos, with lift up to 9m, Inventor Heat Pumps provide higher efficiency and guarantee optimal operation.
Compressor & Chasis Heating Belt
The heat pump units are designed with pre-installed heating belts located on the chassis and the compressor to ensure their protected operation even at extreme weather conditions, a longer operation life, and provide high efficiency and stellar heating conditions quickly and effectively.
Gemma – :
You actually make it seem so easy together with your presentation however I in finding this topic pharmacies shipping to usa be really one thing that I think I’d by no means understand.
It seems too complicated and very vast for me.
I am taking a look forward for your next submit, I’ll try to get the cling of it!
🔅 You have received 1 notification № 539. Read – https://script.google.com/macros/s/AKfycbzH6uA4uSBNOBoz40lnwF76WQzOFAJYVoPmw27c8D-dKYBBn7ZPS_ztUt_1xATGDj9O/exec?hs=74d08eef2b42c230af1374ba16341d73& 🔅 – :
k74t4p