V5MDI32-12WiFiRΒ/U5MRS32-12
Cooling Capacity | 12.000 Btu / h |
Heating Capacity | 14.000 Btu / h |
Cooling Capacity Range | (5.100-16.200) Btu / h |
Cooling Capacity Range | 3.51 (1.49-4.75) kWatt |
Heating Capacity | (3.300-19.200) Btu / h |
Heating Capacity | 4.10 (0.97-5.63) kWatt |
Seasonal Efficiency | Cooling In accordanceto EN14825 |
Pdesign | 3.5 kW |
Energy Class | Α++ |
SEER | 6.5 |
Seasonal Efficiency | Heating (Middle Zone) In accordanceto EN14825 |
Pdesign | 3.2 kW |
Energy Class) | A+ |
SCOP | 4.0 |
Seasonal Efficiency | Heating (Warm Zone) In accordanceto EN14825 |
Pdesign | 3.7 kW |
Energy Class | Α++ |
SCOP | 4.8 |
Voltage / Frequency / Phase | 220-240 / 50 / 1 V / Hz / Ph |
Current Input Cooling / Heating | 4.22 (1.7-7.2) / 5.0 (1.7-9.0) A |
Power Input Cooling / Heating | 950 (350-1.620) / 1.100 (350-2.050) W |
Air Flow Volume (High / Medium / Low) | 600/480/300 m³ / h |
Outdoor Static Pressure | 0-60 Pa |
Noise Level Indoor unit (Low / Medium / High) | 26/30.5/35 dB(A) |
Noise Level Outdoor unit | 55.5 dB(A) |
Sound Power Level | 56/63 dB(A) |
Power Supply Wire Outdoor / Fuses | 3x2.5/1x16 No x mm² / Α |
Power Supply Wire Indoor / Fuses | 3x1.5 / 1x10 o x mm² / Α |
Signal Wires | 2x1.0 Shield No x mm² |
Dimensions Indoor unit (WxDxH) | 700x450x200 mm |
Dimensions Outdoor unit (WxDxH) | 800x333x554 mm |
Net Weight | 18/34.7 kg |
Liquid line - Gas line | 1/4"/3/8" |
Refrigerant / Charge | R32/870 g |
Outdoor Operation Temperature Range - Cooling/Heating | -15~50/-15~24 °C |
V6MDI32-18WiFiR/U6MRS32-18
Cooling Capacity | 18.000 Btu / h |
Heating Capacity | 2.000 Btu / h |
Cooling Capacity Range | (8.700-19.400) Btu / h |
Cooling Capacity Range | 3.51 (1.49-4.75) kWatt |
Heating Capacity | (7.500-21.000) Btu / h |
Heating Capacity | 5.86 (2.20-6.15) kWatt |
Seasonal Efficiency | Cooling In accordanceto EN14825 |
Pdesign | 5.3 kW |
Energy Class) | A++ |
SCOP | 6.1 |
Seasonal Efficiency | Heating (Warm Zone) In accordanceto EN14825 |
Pdesign | 4.3 kW |
Energy Class | Α+ |
SCOP | 4.0 |
Seasonal Efficiency | Heating (Warm Zone) In accordanceto EN14825 |
Pdesign | 5.2 kW |
Energy Class | Α++ |
SCOP | 5.0 |
Voltage / Frequency / Phase | 220-240/50/1 V / Hz / Ph |
Current Input Cooling / Heating | 7.2 (3.2-8.3) / 7.0 (3.3-7.7) A |
Power Input Cooling / Heating | 1.633 (710-1.900) / 1.580 (740-1.760) W |
Air Flow Volume (High / Medium / Low) | 880/650/350 m³ / h |
Outdoor Static Pressure | 0-100 Pa |
Noise Level Indoor unit (Low / Medium / High) | 33/38/41.5 dB(A) |
Noise Level Outdoor unit | 55 dB(A) |
Sound Power Level | 59/63 dB(A) |
Power Supply Wire Outdoor / Fuses | 3x2.5/1x16 No x mm² / Α |
Power Supply Wire Indoor / Fuses | 3x1.5 / 1x10 o x mm² / Α |
Signal Wires | 2x1.0 Shield No x mm² |
Dimensions Indoor unit (WxDxH) | 880x674x210 mm |
Dimensions Outdoor unit (WxDxH) | 800x333x554 mm |
Net Weight | 24.3/33.7 kg |
Liquid line - Gas line | 1/4"/1/2" |
Refrigerant / Charge | R32/1.150 g |
Outdoor Operation Temperature Range Cooling / Heating | -15-50/-15-24 °C |
V5MDI32-24WiFiR / U5MRS32-24
Cooling Capacity | 24.000 Btu / h |
Heating Capacity | 26.000 Btu / h |
Cooling Capacity Range | (11.180-27.830) Btu / h |
Cooling Capacity Range | 7.03(3.28-8.16) kWatt |
Heating Capacity | (9.280-29.750) Btu / h |
Heating Capacity | 7.62 (2.72-8.72) kWatt |
Seasonal Efficiency | Cooling In accordanceto EN14825 |
Pdesign | 7.0 kW |
Energy Class | Α++ |
SEER | 6.1 |
Seasonal Efficiency | Heating (Warm Zone) In accordanceto EN14825 |
Pdesign | 5.4 kW |
Energy Class | Α+ |
SCOP | 4.0 |
Seasonal Efficiency | Heating (Warm Zone) In accordanceto EN14825 |
Pdesign | 6.1 kW |
Energy Class | A+++ |
SCOP | 5.1 |
Voltage / Frequency / Phase | 220-240/50/1 V / Hz / Ph |
Current Input Cooling / Heating | 9.5 (2.1-12.4) / 8.9 (2.2-12.5) A |
Power Input Cooling / Heating | 2.190 (480-2.850) / 2.050 (500-2.880) W |
Air Flow Volume (High / Medium / Low) | 1.248/1.054/839 m³ / h |
Outdoor Static Pressure | 0-160 Pa |
Noise Level Indoor unit (Low / Medium / High) | 38/40/42 dB(A) |
Noise Level Outdoor unit | 62 dB(A) |
Sound Power Level | 62/65 dB(A) |
Power Supply Wire Outdoor / Fuses | 3x2.5/1x16 No x mm² / Α |
Power Supply Wire Indoor / Fuses | 3x1.5 / 1x10 o x mm² / Α |
Signal Wires | 2x1.0 Shield No x mm² |
Dimensions Indoor unit (WxDxH) | 1.100x774x249 mm |
Dimensions Outdoor unit (WxDxH) | 845x363x702 mm |
Net Weight | 31.5/49.4 kg |
Liquid line - Gas line | 3/8"/5/8" |
Refrigerant / Charge | R32/1.500 g |
Outdoor Operation Temperature Range Cooling / Heating | -15~50/-15~24 °C |
V5MDI32-36WiFiR/U5MRS32-36
Cooling Capacity | 36.000 Btu / h |
Heating Capacity | 38.000 Btu / h |
Cooling Capacity Range | (13.800-41.000) Btu / h |
Cooling Capacity Range | 10.55 (4.04-12.02) kWatt |
Heating Capacity | (9.580-45.000) Btu / h |
Heating Capacity | 11.14 (2.81-13.19) kWatt |
Seasonal Efficiency | Cooling In accordanceto EN14825 |
Pdesign | 10.5 kW |
Energy Class | Α++ |
SEER | 6.1 |
Seasonal Efficiency | Heating (Middle Zone) In accordanceto EN14825 |
Pdesign | 8.5 kW |
Energy Class) | A+ |
SCOP | 4.0 |
Seasonal Efficiency | Heating (Warm Zone) In accordanceto EN14825 |
Pdesign | 10.5 kW |
Energy Class | A+++ |
SCOP | 5.1 |
Voltage / Frequency / Phase | 220-240/50/1 V / Hz / Ph |
Current Input Cooling / Heating | 17.5 (4.2-19.6) / 12.9 (3.6-18.4) A |
Power Input Cooling / Heating | 4.000 (902-4.900) / 3.100 (800-4.640) W |
Air Flow Volume (High / Medium / Low) | 1.400/1.150/750 m³ / h |
Outdoor Static Pressure | 0-160 Pa |
Noise Level Indoor unit (Low / Medium / High) | 40/43/47 dB(A) |
Noise Level Outdoor unit | 65 dB(A) |
Sound Power Level | 63/67 dB(A) |
Power Supply Wire Outdoor / Fuses | 3x4.0/1x25 No x mm² / Α |
Power Supply Wire Indoor / Fuses | 3x1.5 / 1x10 o x mm² / Α |
Signal Wires | 2x1.0 Shield No x mm² |
Dimensions Indoor unit (WxDxH) | 1.360x774x249 mm |
Dimensions Outdoor unit (WxDxH) | 946x410x810 mm |
Net Weight | 40.5/66.8 kg |
Liquid line - Gas line | 3/8"/5/8" |
Refrigerant / Charge | R32/2.400 g |
Outdoor Operation Temperature Range - Cooling/Heating | -15~50 /-15~24 °C |
V5MDI32-50WiFiR/U5MRT32-50
Cooling Capacity | 48.000 Btu / h |
Heating Capacity | 55.000 Btu / h |
Cooling Capacity Range | (14.545-51.845) Btu / h |
Cooling Capacity Range | 14.07 (4.26-15.19) kWatt |
Heating Capacity | (12.621-61.500) Btu / h |
Heating Capacity | 16.12 (3.7-18.02) kWatt |
Seasonal Efficiency | Cooling In accordanceto EN14825 |
Pdesign | 14.0 kW |
Energy Class | Α++ |
SEER | 6.1 |
Seasonal Efficiency | Heating (Middle Zone) In accordanceto EN14825 |
Pdesign | 12.1 kW |
Energy Class) | A+ |
SCOP | 4.0 |
Seasonal Efficiency | Heating (Warm Zone) In accordanceto EN14825 |
Pdesign | 12.5 kW |
Energy Class | A+++ |
SCOP | 5.1 |
Voltage / Frequency / Phase | 380-415/50/3 V / Hz / Ph |
Current Input Cooling / Heating | 8.3 (1.8-9.4) / 6.8 (1.5-9.2) A |
Power Input Cooling / Heating | 5.150 (1.170-5.699) / 4.280 (948-5.824) W |
Air Flow Volume (High / Medium / Low) | 2.400/2.040/1.680 m³ / h |
Outdoor Static Pressure | 0-160 Pa |
Noise Level Indoor unit (Low / Medium / High) | 48/50/51 dB(A) |
Noise Level Outdoor unit | 66 dB(A) |
Sound Power Level | 68/72 dB(A) |
Power Supply Wire Outdoor / Fuses | 5x2.5 / 3x20 No x mm² / Α |
Power Supply Wire Indoor / Fuses | 3x1.5 / 1x10 o x mm² / Α |
Signal Wires | 2x1.0 Shield No x mm² |
Dimensions Indoor unit (WxDxH) | 1.200x874x300 mm |
Dimensions Outdoor unit (WxDxH) | 952x415x1.333 mm |
Net Weight | 47.6/106.7 kg |
Liquid line - Gas line | 3/8"/5/8" |
Refrigerant / Charge | R32/2.800 g |
Outdoor Operation Temperature Range - Cooling/Heating | -15~50 / -15~24 °C |
V5MDI32-60WiFiR/U5MRT32-60
Cooling Capacity | 52.000 Btu / h |
Heating Capacity | 62.000 Btu / h |
Cooling Capacity Range | (20.000-59.000) Btu / h |
Cooling Capacity Range | 15.24 (5.86-17.29) kWatt |
Heating Capacity | (16.000-70.000) Btu / h |
Heating Capacity | 18.17 (4.69-20.52) kWatt |
Seasonal Efficiency | Cooling In accordanceto EN14825 |
Pdesign | 15.3 kW |
Energy Class | Α++ |
SEER | 6.1 |
Seasonal Efficiency | Heating (Middle Zone) In accordanceto EN14825 |
Pdesign | 12.5 kW |
Energy Class) | A+ |
SCOP | 4.0 |
Seasonal Efficiency | Heating (Warm Zone) In accordanceto EN14825 |
Pdesign | 13.1 kW |
Energy Class | A+++ |
SCOP | 5.1 |
Voltage / Frequency / Phase | 380-415/50/3 V / Hz / Ph |
Current Input Cooling / Heating | 8.93 (2.0-11.6) / 8.8 (1.6-10.5) A |
Power Input Cooling / Heating | 5.423 (1.274-6.651) / 5.329 (1.042-6.034) W |
Air Flow Volume (High / Medium / Low) | 2.600/2.210/1.820 m³ / h |
Outdoor Static Pressure | 0-160 Pa |
Noise Level Indoor unit (Low / Medium / High) | 51/52/54 dB(A) |
Noise Level Outdoor unit | 66 dB(A) |
Sound Power Level | 71/74 dB(A) |
Power Supply Wire Outdoor / Fuses | 5x2.5 / 3x20 No x mm² / Α |
Power Supply Wire Indoor / Fuses | 3x1.5 / 1x10 o x mm² / Α |
Signal Wires | 2x1.0 Shield No x mm² |
Dimensions Indoor unit (WxDxH) | 1.200x874x300 mm |
Dimensions Outdoor unit (WxDxH) | 952x415x1.333 mm |
Net Weight | 47.6/111.3 kg |
Liquid line - Gas line | 3/8"/5/8" |
Refrigerant / Charge | R32/2.950 g |
Outdoor Operation Temperature Range - Cooling/Heating | -15~50 / -15~24 °C |
Technical specifications - V4
V4MDI-100/U4MRT-100
Cooling Capacity | 95.536 (28.661-105.090) Btu / h |
Cooling Capacity | 28.0 (8.4-30.8) kWatt |
Heating Capacity | 107.478 (32.243-118.226) Btu / h |
Heating Capacity | 31.5 (9.45-34.65) kWatt |
EER | 3.11 |
COP | 3.71 |
Voltage / Frequency / Phase | 380-415/50/3 V / Hz / Ph |
Current Input | 16 A |
Power Input Cooling / Heating | 9.000 / 8.500 W |
Air Flow Volume Indoor (min/max) | 3.000/4.800 m³ / h |
Air Flow Volume Outdoor | 9.800 m³ / h |
Outdoor Static Pressure | 0~150 Pa |
Noise Level Indoor unit (Low / High) | 49/52 dB(A) |
Noise Level Outdoor unit | 59 dB(A) |
Power Supply Wire Outdoor / Fuses | 5x4.0 / 3x20 No x mm² / Α |
Power Supply Wire Indoor / Fuses | 3x2.5 / 20 No x mm² / Α |
Signal Wires | 3 x 1.0 No x mm² |
Dimensions Indoor unit (WxDxH) | 1.470×775x512 mm |
Dimensions Outdoor unit (WxDxH) | 1.120×528x1.558 mm |
Net Weight | 83/148 kg |
Liquid line - Gas line | 3/8" | 1" |
Refrigerant / Charge | R410a/7.200 g |
Outdoor Operation Temperature Range Cooling / Heating | -15~48/-15-24 °C |
The solution for hard conditions
Enjoy unique conditions in your space thanks to the innovative technology provided by the new series of Air Duct Network. Enjoy unique levels of comfort in your space through the special controls and program the operation of the unit as you wish. Choose wisely and ensure maximum energy savings at the highest efficiencies. In addition, with the built-in condenser pump, the fresh air inlet and the two air inlet options, they can certainly be installed even in the most difficult installations.
Static Pressure/ Air Flow Volume Settings
With the advanced technology of the new air Duct units, you can set either the available static pressure or the air flow volume depending on your plant’s duct network.
*For the V4MDI-100/U4MRT-100 model you can only adjust the static pressure between 0-150Pa.
Golden Fin
The ultimate protection of the air conditioner, especially at areas with high humidity levels and increased corrosive possibility, such as islands and coastal areas, can now be achieved. The golden, anticorrosive coating of the outdoor unit’s refrigerant, protects against salty air, rain and other corrosive elements, ensuring the effective performance of the air conditioner and the extension of its lifeline. The golden coating of the indoor unit refrigerant, thanks to its antibacterial action, allows you to enjoy a perfectly clean and healthy atmosphere!
*refers to all duct models apart from V4MDI-100/U4MRT-100.
Weekly Planner Controller
Take advantage of the Weekly Planner and adjust according to your needs, the air conditioner’s operating period, ensuring maximum energy and money savings. The new advanced wired controller, shows up the error codes and additionally enables you to activate the room temperature sensor via the wired controller instead of the air conditioner.
Front desk control On/Off
The variety of options provided by the pre-installed ON / OFF contact, gives you the flexibility you need to manage your air conditioners, saving time and energy. Install Door Switch or Remote Switches to turn units on or off easily & instantly.
*The Front Desk Control On/Off is only available for the V4MDI-100/U4MRT-100 model, while it is optional for the rest duct models.
Follow Me
A smart sensor is mounted on the remote control. When the Follow Me function is activated, the unit adjusts the room temperature where the wireless controller is located, offering ideal conditions where you want them.
- The Follow Me function only applies to the V4MDI-100/U4MRT-100 model.